Viessmann Vitodens 200-W Installation And Service Instructions Manual page 60

125 and 150 kw wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Further details regarding the individual steps
D Heating circuit pump "OFF"
E Heating circuit pump "ON"
Changing the standard set room temper-
ature
Operating instructions
Reduced set room temperature
90
A
C
D
Example 2: Change in the reduced set
room temperature from 5 °C to 14 °C
A Boiler water temperature or flow
temperature in °C
B Outside temperature in °C
C Set room temperature in °C
D Heating circuit pump "OFF"
E Heating circuit pump "ON"
Changing the reduced set room temper-
ature
Operating instructions
60
-20
B
E
(cont.)
Changing the slope and level
Individually adjustable for each heating
circuit.
90
+20
Outside temperature in °C
A Changing the slope
B Changing the level (vertical parallel
offset of the heating curve)
Extended menu:
1. å
2. "Heating"
3. Select heating circuit.
4. "Heating curve"
5. "Slope" or "Level"
6. Select heating curve according to the
system requirements.
3.5
1.4
A
B
0.2
-20