Fault codes
(cont.)
Dis-
Const.
played
fault
code
d8
X
dA
db
dC
dd
dE
dF
Weath.-
System char-
comp.
acteristics
X
Control mode
X
Control mode
without room
influence
X
Control mode
without room
influence
X
Control mode
without room
influence
X
Control mode
without room
influence
X
Control mode
without room
influence
X
Control mode
without room
influence
Troubleshooting
Cause
Measures
Input DE3 re-
Remove fault at
ports a fault at
appliance con-
extension
cerned.
EA1
Short circuit,
Check room tem-
room temper-
perature sensor,
ature sensor,
heating circuit 1.
heating circuit
1 (without
mixer)
Short circuit,
Check room tem-
room temper-
perature sensor,
ature sensor,
heating circuit 2.
heating circuit
2 (with mixer)
Short circuit,
Check room tem-
room temper-
perature sensor,
ature sensor,
heating circuit 3.
heating circuit
3 (with mixer)
Lead break,
Check room tem-
room temper-
perature sensor for
ature sensor,
heating circuit 1
heating circuit
and remote control
1 (without
settings.
mixer)
Lead break,
Check room tem-
room temper-
perature sensor for
ature sensor,
heating circuit 2
heating circuit
and remote control
2 (with mixer)
settings.
Lead break,
Check room tem-
room temper-
perature sensor for
ature sensor,
heating circuit 3
heating circuit
and remote control
3 (with mixer)
settings.
127