Rear Vent, Wall Mounted Termination Graph; Standard Rear Vent, (No Elbows Or Offsets); Rear Vent, Wall Mounted Termination (Two Elbows); Section 3-3-2: Venting Components - Montigo H38DF Installation & Maintenance Manual

Indoor residential fireplace
Table of Contents

Advertisement

H*38DF Gas Fireplace
nOTE:
18" MaX. horizontal
run with no vertical lift.
Hearth
Figure 17a. Straight run, Rear Vented, wall mounted termination for H*38DF*,
Figure 17.
Flex or Rigid
Section
Figure 17b. Rear Vented, wall mounted Multi-elbow termination installation.
Installation for H*38DF* must have a minimum vertical rise of 52".The vent run
must comply with the Venting Graph for Rear vent, wall mounted terminations,
Figure 17.
Please Refer to your Building Envelope Engineer
or waterproofing Consultant for a review of aLL
penetrations through exterior walls or the roof.
Page 14
Installation
PXT Extension
RHS101 Heat
Shield
Termination
18" MaX.
28 3/4"
Exterior
Wall
30" Max.
23 1/4"
Min.
52" Min.
18"
Max.
28 3/4"
IMPORTanT:
Section 3-3-2:
VEnTInG COMPOnEnTS
The following components and associated Montigo part numbers are
available for installation of a Wall Mounted Termination. Use only Montigo
Vent Components. Use of non-Montigo parts will void the warranty and
may impede operation of the fireplace.
a - Termination
B - Frame Kits
C - Flex Sections
D - Rigid Sections
E - Elbows
Connection and installation of the vent components should adhere to
the following guidelines:
Use any combination of rigid and Flex pipe as required.
Flex sections may be stretched up to 50% of their total length
(e.g. a 24" section maybe stretched to 36").
Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue..
Ensure the pipe ends male to female slide in a minimum of 1
1/2" of overlap.
Ensure all runs are supported with a minimum of 3 supports
per 10' of venting.
When hanging/ supporting venting, ensure that 1" clearance
is maintained on sides and bottom of vent runs and 2" above
horizontal vent runs to any combustible material.
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
Place the springs, supplied with the pipe kit, between the outer
and inner pipes to keep the pipes separate and avoid any
possible hot spots.
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
When penetrating a combustible ceiling, a ceiling firestop must be used.
Montigo recommends that all exterior corners and joints be sealed
with exterior caulking however we encourage you to consult
your Building Envelope Engineer or Waterproofing Consultant
for further recommendations.
PTO-4
(3" Length)
PTO-4F
(3" Length)
MSR
(Stucco Frame)
MOSR
(Stucco Frame)
BSR-4
(4" Brick Frame)
BSR-6
(6" Brick Frame)
PFL - 1
(12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2
(24" f/f Section)
PFL - 3
(36" f/f Section)
PFL - 4
(48" f/f Section)
PFL - 6
(72" f/f Section)
PXT - 5
(5" f/f Section)
PXT - 10 (10" f/f Section)
PEXT - 1 (12" f/f Section)
PXT - 20 (20" f/f Section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
PEXT - 6 (72" m/f Section)
PEL-90MM (m/m 90º Elbow)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)