Standard Roof Vent (One Elbows No Offsets); Section 3-2-2: Venting Components - Montigo H38DF Installation & Maintenance Manual

Indoor residential fireplace
Table of Contents

Advertisement

H*38DF Gas Fireplace
PVTK1
Termination
Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend).

Section 3-2-2: VEnTInG COMPOnEnTS

Select from the following components and associated Montigo part
numbers for installation of a Roof Mounted Termination. Use only
Montigo Vent Components. Use of non-Montigo parts will void the
warranty and may impede operation of the fireplace.
a - Termination
B - Flex Sections
C - Rigid Sections
D - Elbows
E - Support Ring & Plate
F - Firestop
G - Roof Flashing
Page 10
Installation
Support plate
32' max
Support ring
18"
Max.
PVTK-1
PFL - 1
(12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2
(24" f/f Section)
PFL - 3
(36" f/f Section)
PFL - 4
(48" f/f Section)
PFL - 6
(72" f/f Section)
PXT - 5
(5" f/f Section)
PXT - 10 (10" f/f Section)
PEXT - 1 (12" f/f Section)
PXT - 20 (20" f/f Section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
PEXT - 6 (72" m/f Section)
PEL-90MM (m/m 90º Elbow)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)
PSPXT-8
PS-8
PRF-7
(1/12 - 7/12 pt.)
PRF-12
(7/12 - 12/12 pt.)
Connection and installation of the vent components should adhere
to the following guidelines:
Use any combination of rigid and Flex pipe as required.
Flex sections may be stretched up to 50% of their total length
(e.g. a 24" section maybe stretched to 36").
Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue.
Ensure the pipe ends male to female slide in a minimum of 1
1/2" of overlap.
Ensure all runs are supported with a minimum of 3 supports per
10' of venting.
When hanging/ supporting venting, ensure that 1" clearance
is maintained on sides and bottom of vent runs and 2" above
horizontal vent runs to any combustible material.
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
Place the springs, supplied with the pipe kit, between the outer
and inner pipes to keep the pipes separate and avoid any
possible hot spots.
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
When penetrating a combustible ceiling, a ceiling firestop must
be used.
IMPORTanT:
Please Refer to your Building Envelope Engineer
or waterproofing Consultant for a review of aLL
penetrations through exterior walls or the roof.
Montigo recommends that all exterior corners and joints be sealed
with exterior caulking however we encourage you to consult
your Building Envelope Engineer or Waterproofing Consultant
for further recommendations.
XG0147 - 042811

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl38dfHr38df

Table of Contents