Top Vent, Wall Mounted Termination (45° Corner) - Montigo H38DF Installation & Maintenance Manual

Indoor residential fireplace
Table of Contents

Advertisement

45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the
PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace into
position and attach to the termination.
Figure 16b. Corner installation.
45° or less Corner Installation.
Use an PTO-3 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
Figure 16c. Flex installation. (NG Models Only)
note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a PFL-12 (f/f) flexible pipe, and a termination with or without
a mounting frame.
XG0147 - 042811
Installation
notes wall Mounted Terminations: Rear Vent
Heat Shield
The Venting Graph
PXT-18
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
PEL-45 Elbow
flange of the termination. Plot on the Venting Graph Figure 17 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
PEL-90 Elbow
installation is acceptable.
Example a: (acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 138", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal
run to the wall flange of the vent termination is 96", this would be
would nOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and
the horizontal run to the wall flange of the vent termination is 120",
this would nOT be an acceptable installation.
Heat Shield
Figure 17. Rear Vent Venting Graph for wall mounted terminations.
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 17.
Fireplace must be converted to Rear Vent configuration prior to
running vent, see Figure 7 and 8.
Acceptable vent run
within non-shaded area.
C
B
52"
48"
28 3/4"
18"
H*38DF Gas Fireplace
A
Unacceptable vent run
within shaded area.
If your installation does not fall
within the venting graph para-
meters, please contact Montigo
for Power Venting options.
Page 13