Rear Vent, Wall Mounted Termination Graph, H*38Pf - Montigo H38DF PFC Installation & Maintenance Manual

Peninsula indoor residential gas fireplace
Table of Contents

Advertisement

H*38DF PFC Peninsula Gas Fireplace
Notes Wall Mounted Terminations: REAR VENT
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 14 or 14a.
Fireplace must be converted to Rear Vent configuration prior to
running vent, see Figure 8 and 8a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar to
the wall flange of the termination. Plot on the Venting Graph Figure 14
or 14a with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 138", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 60." and the horizontal
run to the wall flange of the vent termination is 84", this would
NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and
the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation.
Acceptable vent run
within non-shaded area.
B
53"
42"
33"
12"
Figure 14. H38PF* or HL38PF* Rear Vent Venting Graph for wall mounted
terminations.
Page 14
Installation
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall within
the venting graph parameters, please
contact a local Montigo dealer for
Power Venting options.
Acceptable vent run
within non-shaded area.
B
60"
42 "
33 "
12 "
Figure 14a. HP38PF* Rear Vent Venting Graph for wall mounted terminations.
12"
MAX.
Figure 15. H38PF* , HL38PF* or HP38PF* Straight run, Rear Vented, wall
mounted termination. The vent run must comply with the Venting Graph for
Rear vent, wall mounted terminations, Figure 14 or 14a.
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall within
the venting graph parameters, please
contact a local Montigo dealer for
Power Venting options.
NOTE: 12" MAX.
horizontal run with
no vertical lift.
Exterior
ll
Wa
Heat
Shield
Termination
33"
Hearth
XG0816 - 011012.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp38df pfcHl38df pfcHl38df pfc

Table of Contents