HEAT EXCHANGER
COOLING SYSTEM
HEAT EXCHANGER
1. Measure:
S Filler cap opening pressure
Cap opens at pressure below the speci-
fied pressure ! Replace.
Cap opening pressure:
95 X 125 kPa
(0.95 X 1.25 kg/cm
13.58 X 17.87 psi)
Measurement steps:
D Attach the cooling system tester
(90890-01325, YU-24460-01) to the
coolant filler cap
D Apply the specified pressure for 10
seconds, and make sure there is no
pressure drop.
–37–
COOL
2
,
1
2
.