9. Auto White Balance 3200K Standard Data Input

RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "Auto White Balance 3200K Standard Data Input" is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
3
6
B6
03
4
7
5D
5
6
13
D
5D
6
6
37
02
7
6
01
0B
8
6
02
9
6
01
00
10
6
37
01
11
6
01
C1
12
6
02
13
6
01
00
14
7
5E
15
6
13
D
5E
16
6
37
04
17
6
01
0B
18
6
02
19
6
01
00
20
6
37
03
21
6
01
C1
22
6
02
23
6
01
00
23
7
5F
24
6
13
D
25
6
37
06
26
6
01
0B
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting ". (Refer to page 5-14)
Read the data, and this data
is named D
.
5D
Press PAUSE button. (Note 2)
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button. (Note 2)
Check the data changes to
"01".
Press PAUSE button.
Read the data, and this data
is named D
.
5E
Press PAUSE button. (Note 2)
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button. (Note 2)
Check the data changes to
"01".
Press PAUSE button.
Read the data, and this data
is named D
.
5F
5F
Press PAUSE button. (Note 2)
Order Page Address Data
27
6
02
28
6
01
29
6
37
30
6
01
31
6
02
Note 2: The adjustment data will be automatically input to page:
F, address: 70 to 77, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
13
3
6
37
4
6
B6
5
5-21
DSC-P31/P31M
Procedure
Check the data changes to
"01".
00
Press PAUSE button.
05
C1
Press PAUSE button. (Note 2)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
00
00
00
Release the data setting
performed at step 1. (Refer to
page 5-13)

Advertisement