Picture Frame Setting (All White Frame); Auto White Balance Standard Data Input - Sony DCR-HC65 Adjusting Manual

Hide thumbs Also See for DCR-HC65:
Table of Contents

Advertisement

DCR-HC65

11. Picture Frame Setting (All White Frame)

When performing "Auto White Balance Standard Data Input", "LV
Standard Data Input", "Auto White Balance Adjustment" and "White
Balance Check", set the picture frame to "All white frame".
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Note2: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
1
2
3
0
03
4
1
5
0
03
6
1
7
0
03
8
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason reset them in the
following method.
Order Page Address Data
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
Processing after Completing Adjustments
After completing "Auto White Balance Standard Data Input", "LV
Standard Data Input", "Auto White Balance Adjustment" and "White
Balance Check", release the data setting.
Order Page Address Data
1
6
90
2
6
91
3
6
92
4
6
93
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Video terminal of AUDIO/VIDEO jack
TV monitor (Under scan mode)
Whole of the screen is white
Procedure
While observing the TV monitor
screen, adjust the zoom to TELE
side from WIDE side, and stop it
when the black frame of the chart
disappears.
Check that whole of the screen is
white.
18
Set the data.
Read the XH and XL data. (Note2)
22
Set the data.
Read the YH and YL data. (Note2)
00
Set the data.
Perform the following adjustments.
Procedure
Set the data.
Set the data.
Set the data.
Set the data.
79
Set the data, and press PAUSE
button.
Procedure
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.

12. Auto White Balance Standard Data Input

Adjust the white balance reference at 3200K.
Subject
Adjustment Page
Adjustment Address
Note1: This adjustment should be carried out upon completion of "Color
reproduction adjustment".
Note2: Perform "11. Picture Frame Setting (All White Frame)" before
this adjustment.
Note3: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
Note4: After the power is turned on, this adjustment can be done only
once.
Note5: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
1
2
0
01
3
0
10
4
5
6
01
6
6
01
7
6
02
Note6: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3.
Processing after Completing Adjustments
Order Page Address Data
1
0
10
2
6
01
3
0
01
4
6-30
Clear chart (All white frame) (Note2)
F
14 (Note3)
2E to 31
E8 to F3
Procedure
Check that the whole of the screen
is white. If not, perform "11.
Picture Frame Setting (All White
Frame)".
01
Set the data.
00
Set the data.
Wait for more than 2 sec.
43
Set the data, and press PAUSE
button.
41
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
Procedure
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
Perform "LV Standard Data
Input".

Advertisement

Table of Contents
loading

Table of Contents