Strobe White Balance Adjustment - Sony DSC-P31M Service Manual

Digital still camera
Table of Contents

Advertisement

19. Strobe White Balance Adjustment

Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(1 m from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B6, B7, DB to EF
Specified Value
Y level data: 03 to 08
R-Y level data:
FA to FF or 00 to 06 (Note 4)
B-Y level data:
FA to FF or 00 to 06 (Note 4)
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Perform this adjustment in the Flash adjustment box.
Note 3: Refer to "4. Preparing the Flash adjustment box".
(See page 5-7)
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 5: "Strobe White Balance Adjustment" is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
1
2
3
4
1E
4
4
1E
00
5
6
2C
01
6
6
90
00
7
6
91
00
8
6
92
FF
9
6
93
FF
10
6
6C
01
11
6
01
79
12
6
07
13
6
01
67
14
15
6
02
16
F
E8
17
6
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
B-Y level data
R-Y level data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting ". (Refer to page 5-14)
Note down the data.
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
Check that the displayed data
satisfies the Y level specified
value.
Press PAUSE button.
Order Page Address Data
18
6
01
19
20
6
02
21
6
01
22
6
01
23
24
6
02
25
6
01
26
6
01
27
28
6
02
29
6
01
30
6
01
31
32
6
02
33
6
01
34
6
01
35
36
6
02
37
EA
38
F
EC
EE
39
0
03
40
1
Note 6: The adjustment data will be automatically input to page:
F, address: B6 to B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
90
3
6
91
4
6
92
5
6
93
6
6
2C
7
6
6C
8
0
03
9
4
1E
10
5-31
DSC-P31/P31M
Procedure
67
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
B9
Press PAUSE button. (Note 6)
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
E7
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
Wait for 1 second.
Check that the displayed data
satisfies the Y level specified
value.
02
"Check that the R-Y, B-Y
level data (Note 4) satisfies
the specified value. "
Procedure
00
Press PAUSE button.
00
00
00
00
00
00
00
Set data noted down at step
3, and press PAUSE button.
Release the data setting
performed at step 1. (Refer to
page 5-13)