11. Auto White Balance 3200K Standard Data Input

Adjust the white balance standard data at 3200K.
Mode
STILL (P AUTO) (P)
Subject
Clear chart (Standard picture frame)
Measurement Point
Data of page: 6E, address: 4F
Measuring Instrument
Adjustment Page
6E
Adjustment Address
04 to 21, 47, 4F
Specified value
00
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address:
01, and Set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
1
2
3
Data contents will be released
in Supplement.
4
6E
4F
FF
5
60
36
01
6
60
01
0B
7
8
60
02
9
6E
4F
Note2: The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page Address Data
1
60
01
00
2
60
36
00
3
4
60
37
5
Procedure
Install the Clear chart.
Check that "1. Data Setting
during Camera System
Adjustments" is performed.
Check the picture frame. If
deviated, perform "5. Picture
Frame Setting".
Set the data.
Set the data.
Set the data.
Wait for 5 sec.
Read the data, and check it is "01".
Read the data, and check it
satisfies the specified value.
Procedure
Set the data.
Set the data.
Wait for 1 sec.
Read the data, and check it is "00".
Perform "Auto White Balance
3200K & 5800K Standard Data
Input (Capture Mode)".
If finish the camera system
adjustments, release the data
setting.
(See "1. Data Setting during
Camera System Adjustments".)

12. Auto White Balance 5800K Standard Data Input

Adjust the white balance standard data at 5800K.
Mode
Subject
Filter
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address:
01, and Set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
1
Data contents will be released
2
in Supplement.
3
4
6E
4F
5
60
36
6
60
01
7
8
60
02
9
6E
4F
Note2: The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page Address Data
1
60
01
2
60
36
3
4
60
37
5
6-19
DSC-F828
STILL (P AUTO) (P)
Clear chart (Standard picture frame)
Filter C14 for color temperature
correction
Data of page: 6E, address: 4F
6E
24 to 41, 49
00 to FF
Procedure
Place the C14 filter for color
temperature correction on the
lens.
Check that "1. Data Setting
during Camera System
Adjustments" is performed.
Check the picture frame. If
deviated, perform "5. Picture
Frame Setting".
FF
Set the data.
02
Set the data.
A5
Set the data.
Wait for 5 sec.
Read the data, and check it is "01".
Read the data, and check it
satisfies the specified value.
Procedure
00
Set the data.
00
Set the data.
Wait for 1 sec.
Read the data, and check it is "00".
Perform "Auto White Balance
3200K & 5800K Standard Data
Input (Capture Mode)".
If finish the camera system
adjustments, release the data
setting.
(See "1. Data Setting during
Camera System Adjustments".)

Hide quick links: