Auto White Balance 3200K Check 1 - Sony DSC-P31M Service Manual

Digital still camera
Table of Contents

Advertisement

DSC-P31/P31M

10. Auto White Balance 3200K Check 1

Mode
Subject
Measurement Point
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Checking method:
Order Page Address Data
1
2
3
6
16
4
6
B6
5
6
37
6
7
5D
7
6
13
8
6
01
9
6
02
10
0
03
11
1
12
0
03
13
1
14
0
03
15
1
16
6
01
17
7
5E
18
6
13
19
6
01
20
6
02
21
0
03
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 2)
(75 Ω terminated)
R-Y level data:
FFFE to FFFF or 0000 to 0002
B-Y level data:
FFFE to FFFF or 0000 to 0002
Y level data: 40 to C0
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting ". (Refer to page 5-14)
04
03
0D
Read the data, and this data
is named D
.
5D
D
5D
C1
Press PAUSE button.
Check the data changes to
"01".
2C
Check that the R-Y level data
(Note 2) satisfied the
specified value.
2D
Check that the B-Y level data
(Note 2) satisfied the
specified value.
33
Check that the Y level data
(Note 2) satisfied the
specified value.
00
Press PAUSE button.
Read the data, and this data
is named D
.
5E
D
5E
C1
Press PAUSE button.
Check the data changes to
"01".
2C
Order Page Address Data
22
1
23
0
03
24
1
25
0
03
26
1
27
6
01
28
7
5F
29
6
13
30
6
01
31
6
02
32
0
03
33
1
34
0
03
35
1
36
0
03
37
1
38
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
B6
3
5-22
Procedure
Check that the R-Y level data
(Note 2) satisfied the
specified value.
2D
Check that the B-Y level data
(Note 2) satisfied the
specified value.
33
Check that the Y level data
(Note 2) satisfied the
specified value.
00
Press PAUSE button.
Read the data, and this data
is named D
.
5F
D
5F
C1
Press PAUSE button.
Check the data changes to
"01".
2C
Check that the R-Y level data
(Note 2) satisfied the
specified value.
2D
Check that the B-Y level data
(Note 2) satisfied the
specified value.
33
Check that the Y level data
(Note 2) satisfied the
specified value.
Perform "Auto white Balance
3200K Check 2".
Procedure
00
Press PAUSE button.
00
Release the data setting
performed at step 1.
(Refer to page 5-13)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc-p31