Index - Mitsubishi Electric FR-A700-A1 Instruction Manual

Dancer control function/tension control function
Table of Contents

Advertisement

Index

6.5 Index

A
Acceleration/deceleration time selection
(X51 signal, X52 signal) ................................................. 16, 46, 56
Acceleration/deceleration time setting
(Pr. 756 to Pr. 761, X51 signal, X52 signal) ...............................46
Adjustment of target position input (Pr. 708, C3, C4, C6, C7, C13,
C15, C31, C33) .......................................................................... 29
Analog input gain selection (X87 signal, X88 signal) ..... 16, 44, 56
Analog input signals and pulse train input signals ...................... 18
Analog output signal for Dancer tension setting
(Pr. 718, Pr. 719, Pr. 733, Pr. 734, Pr. 785, Pr. 787 to Pr. 789) . 51
D
Dancer compensation speed monitor ......................................... 49
Dancer control selection (X85 signal) ............................. 16, 32, 56
Dancer control/Tension control selection
(X83 signal) .................................................. 16, 19, 25, 32, 56, 57
Dancer PID gain adjustment ......................................................24
Dancer position detection (Y54 signal) ...........................17, 27, 56
Dancer roll position detection signal ............................... 16, 27, 56
Dancer roll position deviation monitor ........................................ 49
Dancer roll set point monitor ......................................................49
Dancer roll target position (Pr. 133, Pr. 702, Pr. 731) ................27
Dancer roll target position detection signal ................................ 16
Dancer tension command 2 ....................................................... 49
Dancer tension command monitor ....................................... 49, 51
Dedicated ................................................................................... 56
Dedicated monitor list ................................................................. 49
F
Filter treatment for compensated main rotation speed by winding
diameter calculation (Pr. 769, Pr. 770) .......................................38
I
Inertia compensation .................................................................. 49
Inertia compensation acceleration (X57 signal) ................... 16, 56
Inertia compensation deceleration (X58 signal) ................... 16, 56
Inertia compensation function (Pr. 713 to Pr. 716, X57 signal, X58
signal, X59 signal) ...................................................................... 62
Inertia compensation second acceleration/deceleration time
selection (X59 signal) ........................................................... 16, 56
Initial winding diameter calculation at a start (Pr. 133,
Pr. 712, Pr. 790 to Pr. 796) ........................................................39
Initial winding diameter calculation completion
(Y51 signal) .................................................................... 17, 41, 56
Input method for main speed command (Pr. 732) ...................... 43
Input signal list ...................................................................... 16, 56
Integral term activation (X34 signal) ........................................... 56
Integral term activation signal (X34 signal) .......................... 16, 56
L
Line speed detection signal ............................................16, 33, 56
Line speed input setting (Pr. 763 to Pr. 768) .............................. 33
Line speed monitor .....................................................................49
Line speed pulse monitor ........................................................... 49
Line speed pulse monitor function .............................................. 50
80
M
Main speed command by analog input .......................................44
Main speed command by terminal JOG single-phase pulse train
input (Pr. 384 to Pr. 386, Pr. 703, Pr. 704) .................................45
Main speed monitor ....................................................................49
Main speed setting signal ...............................................16, 43, 56
Material thickness, maximum/minimum winding diameter setting
(Pr. 720 to Pr. 727, Pr. 752 to Pr. 755, X53 signal, X54 signal) .35
Measured dancer roll value monitor ...........................................49
Measured value upper/lower limit detection signal (Pr. 131, Pr. 132)
....................................................................................................29
Mechanical loss compensation ..................................................49
Mechanical loss compensation (Pr. 739 to Pr. 749, Pr. 762) .....64
Minimum/maximum winding diameter selection (X53 signal, X54
signal) .............................................................................16, 35, 56
Multiple monitor (Pr. 52) .............................................................50
O
Offset displacement storage .......................................................16
Offset displacement storage (X33 signal) ..................................56
Operation command source and speed command source
(Pr. 388, Pr. 339) ........................................................................53
Output signal list ...................................................................17, 56
P
PID differential term reset input (X32 signal) ........................16, 56
PID gain switchover (X89 signal, X90 signal) .................16, 29, 56
PID integral term reset input (X30 signal) ............................16, 56
PID lower limit (FDN signal) ...........................................17, 29, 56
PID setting (Pr. 128 to Pr. 130, Pr. 134 to Pr. 137,
Pr. 709, Pr. 710) .........................................................................25
PID upper limit (FUP signal) ...........................................17, 29, 56
R
Regeneration avoidance function (Pr. 882) ................................53
Rotation speed at winding diameter calculated value activation
(Pr. 797) .....................................................................................36
S
Sampling time and restricted increase of winding diameter (Pr. 707,
Pr. 771, Pr. 772, Pr. 786) ...........................................................38
Setting at driving shaft (Pr. 762, Pr. 773, Pr. 774) ......................34
Signal loss detection (Y50 signal) ..................................17, 27, 56
Speed compensation gain selection (X35 signal) ..........16, 31, 56
Speed compensation(Pr. 706, Pr. 798) ......................................31
Speed control P/I gain adjustment (vector control) ....................22
Speed control proportional gain disabled (X93 signal) .........16, 56
Speed control proportional gain selection based on winding
diameter calculation result (Pr. 775 to Pr. 780) ..........................47
Stall operation (X92 signal) ..................................................16, 56
Stall operation signal (Pr. 737, Pr. 738, Pr. 760, X92 signal) .....65
Storage and clear of winding diameter calculation result
(Pr. 781 to Pr. 783, X55 signal) ..................................................37
Storage and clear of winding/unwinding length (Pr. 279 to Pr. 281,
X86 signal, Y53 signal) ...............................................................42
Stored winding diameter clear (X55 signal) ..........................16, 56

Advertisement

Table of Contents
loading

Table of Contents