Analog Output Signal For Dancer Tension Setting (Pr. 718, Pr. 719, Pr. 733, Pr. 734, Pr. 785, Pr. 787 To Pr. 789) - Mitsubishi Electric FR-A700-A1 Instruction Manual

Dancer control function/tension control function
Table of Contents

Advertisement

3.10.6 Analog output signal for dancer tension setting (Pr. 718, Pr. 719, Pr. 733, Pr. 734,
Pr. 785, Pr. 787 to Pr. 789)
Dancer is controlled with an air cylinder. Set an analog signal, which is output for tension setting to control the air cylinder,
with terminal FM/AM.
Parameter
Name
Number
718
Dancer tension setting bias
719
Dancer tension setting gain
Taper setting analog input
733
selection
Dancer tension setting input
734
selection
785
Terminal 4 function setting
787
Taper ratio setting
Winding diameter at taper
788
start
789
Dancer tension setting
Set Pr. 785 Terminal 4 function setting and Pr. 733 Taper setting analog input selection to use the taper setting analog input signal
with an analog input terminal.
(1)
Control diagram
Analog output signal for dancer tension setting
Pr. 789
"9999"
Dancer tension
T
setting Pr. 789
Dancer tension setting
Analog terminal
Pr. 718
input Pr. 734
Bias
Pr. 789 = "9999"
(2)
Connection example
When potentiometer is input
Pr. 733 = "4"
Pr. 785 = "2"
Pr. 787 = "9999"
Pr. 158 = "39"
Use 1/2W1kΩ.
When frequently
set, use 2W1kΩ.
(3)
Tension output command setting
To output tension commands from an inverter, set the AM and FM output terminals as follows.
Signal Type
Dancer tension command
Dancer tension command 2
Use Pr. 900 to calibrate the terminal FM, and Pr. 901 for the terminal AM.
Setting Range
0 to 200%
0 to 200%
3 to 6, 9999
1, 2, 9999
0 to 100%, 9999
1 to 6553mm,
9999
1 to 100, 9999
Analog terminal input
(calibrated) Pr. 733
Pr. 787 = "9999"
r
Pr. 788
100 (Max. winding diameter - Pr. 788)
Pr. 719
Gain
r < Pr. 788
FR-A700-A1
Main speed
2 (0 to 10V)
Dancer signal
1 ( 10V)
Taper ratio setting
10E
4
5
Minimum
Increment
DU LED
1%
39
1%
46
Dedicated monitor function
Initial
Increments
Value
0.1%
0%
0.1%
100%
1
9999
1
9999
0.1%
0%
1mm
9999
0.1
100
Pr. 787
Pr. 787
9999
Taper setting (r - Pr. 788)
T
-
+
Tension setting
AM
When frequently
5
Parameter Setting
Pr.52
Pr.54
PU main
Terminal FM
monitor
39
39
46
46
Remarks
3: terminal 2
4: terminal 4
5: terminal 1
6: terminal 6 (FR-A7AZ)
9999:disabled
1: compensation input
2: analog input signal for taper setting
9999:terminal 4 is disabled
9999:input from the analog terminal
assigned by Pr. 733.
9999:taper start at minimum winding
diameter
9999:input from the analog terminal
assigned by Pr. 734.
Pr. 54 = "39"
X83
Pr. 54 = "46"
Pr. 900
Pr. 15 = "46"
Pr. 901
Pr. 158 "39"
Use 1/2W1kΩ.
set, use 2W1kΩ.
To an electro-pneumatic
converter
Pr.158
Terminal AM
39
46
FM
AM
3
51

Advertisement

Table of Contents
loading

Table of Contents