Buderus 600 - 11R Installation And Servicing Instructions page 35

Gas wall hung boiler condensing
Table of Contents

Advertisement

ATTENTION
If the required connection pressure is
incorrect contact your gas supplier.
WARNING!
Ensure that all disturbed joints and connections are
checked for gas tightness on completion of tasks.
2.2.6 Adjusting the flow temperature
NOTE
Observe stickers attached to Venturi
tubes.
Adjust the knob (fig. 31, item 2) to the desired flow
temperature (table 4) for your particular installation.
NOTE
Factory setting of the controller is "10"
(around 83 °C).
If the flow temperature is set too low, there
is the risc that an external hot water
cylinder cannot achieve a comfortable
enough temperature.
Subject to modifications resulting from technical improvements!
Installation and servicing instructions for wall-mounted condensing gas boiler Buderus 600 - 11R/19R/24R • 02/2006
Fig. 30 Measuring the gas-supply pressure
2
Fig. 31 Control box
Key to fig. 31:
item 1: Cover for second operating level
item 2: Flow temperature controller
item 3: Heat-capacity jumper (do not remove)
item 4: Heating capacity controller
item 5: only used when boiler is in service mode
item 6: only used when boiler is in service mode
Buderus • http://www.buderus-domestic.co.uk
Commissioning
3
11
KW
0
1
1
2
1
10
1
10
4
6
5
1
2
35

Hide quick links: