Reference Material, cont'd
Nominal level ............................... -10 dBV (316 mV) or +4 dBu (1.23 V) (configurable)
Maximum level (600 ohm) ......... >+18 dBu, balanced at 1%THD+N
Unbalanced wired outputs will have unity gain/attenuation. Balanced outputs will result in a
6 dB gain.
Audio output — power amplifier (amplifier models only)
Number/signal type ................... 1 stereo or mono (default = stereo, configurable via front panel or control
Connector ...................................... (1) 4 position screw terminal
Sensitivity ..................................... -22 dBV (80 mVrms, -19.8 dBu) for max. power output (adjustable)
Power bandwidth at rated maximum power output
4 ohm output .................... 10 Hz to 20 kHz, 0.5% THD
8 ohm output .................... 20 Hz to 20 kHz, 0.8% THD
Drive/full power out .................. 40 watts; 20 watts (rms) per channel, 4 or 8 ohm load
Protection ...................................... Input limiting, thermal, short circuit
Control/remote — switcher
Serial control port ........................ 2 RS-232: 1 rear panel 9-pin female D connector, 1 front panel 2.5 mm stereo
Baud rate and protocol ............... 38400, 8-bit, 1 stop bit, no parity
Serial control pin configurations 2 = TX, 3 = RX, 5 = GND (9-pin D)
Ethernet control port ................... 1 RJ-45 female
Ethernet data rate ........................ 10/100Base-T, half/full duplex with autodetect
Ethernet protocol ......................... ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP
Ethernet default settings ............ Link speed and duplex level = autodetected
Web server .................................... Up to 200 simultaneous sessions
Extron remote key pad (SCP) control
IR remote control ......................... IR 402 (optional)
Program control ........................... Extron's configuration program for Windows
Control — relay
Number/type ............................... 6 momentary or latching (configurable via software)
Connectors .................................... (3) 3.5 mm captive screw connectors, 3 pole
Connector configuration ............ Groups A, B, C; each with 1 common and 2 normally open relays (default)
Contact rating ............................... 24 V, 1A
Control — projector
Projector control port; RS-232 .... (1) 3.5 mm captive screw connector, 3-pole
A-4
System 5 IP Switchers • Reference Material
software)
mini jack
tip = TX, ring = RX, sleeve = GND (mini stereo jack)
IP address = 192.168.254.254
Subnet mask = 255.255.0.0,
Default gateway = 0.0.0.0
DHCP = off
7.25 MB nonvolatile user memory
(1) 3.5 mm 5-pole captive screw connector (shared with control module and
IR Link port)
Front panel: 30' maximum, 40 degrees off axis
Rear panel: 38 kHz, hardwired, modulated
Extron's Simple Instruction Set (SIS