Command/Response Table For Special Function Sis Commands - Extron electronics System 5 IP Series User Manual

System switchers with integrated a/v switching, audio amplification, and projector control
Hide thumbs Also See for System 5 IP Series:
Table of Contents

Advertisement

SIS
Programming and Control, cont'd
The syntax for setting a special function for a System 5 IP switcher is
__ is the function number. To view a function's setting, use __#, where __ is the function number. In the
following table the values of the
given in the rightmost column. Special function commands are accessible only through RS-232.

Command/response table for special function SIS commands

Command
Delay times
Most projectors require a certain amount of time during warm-up and cool-down during which they do not accept
commands. You can specify the amount of time for the System 5 IP to wait between sending the projector a power-on or
power-off command and when the next action can occur or the next command can be issued.
Power on delay
24
Example:
Example:
24
Power off delay
Example:
Set the RGB delay
(Triple-Action Switching)
Example:
This command applies to RGB inputs only.
Set the Power Off button delay
Audio settings
Limit audio level on display power-on
Example:
Set the audio output mode
5-32
System 5 IP • SIS
variable are different for each command/function. These values are
X?
ASCII Command Response
(host to System 5)
*1 #
X?
8*1#
1#
*2 #
X?
23*2#
24
*3 #
X?
7*3#
24
*48#
X?
24
*11 #
X?
28*11#
*18 #
X?
Programming and Control
* __ # where
X?
X?
(System 5 IP to host)
and additional descriptions
WarmUp*
0 = 0 seconds,
X?
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).
WarmUp*008
Example: set a 16 second power
on delay.
WarmUp*023
Example:
setting.
CoolDown*
0 = 0 seconds,
X?
1 = 2 seconds,
2 = 4 seconds,... in 2 second
steps up to 150 = 300 seconds.
CoolDown*023
Example:
delay.
RGBDly*
0 = 0.0 seconds (default), 1 = 0.5
X?
seconds, 2 = 1.0 seconds,
... in ½ second steps up to
10 = 5.0 seconds.
RGBDly*07
Example: 3.5 second RGB delay.
PwrOffDly*
0 = the Power Off button
X?
requires no hold delay to issue
power-down commands.
1 = the Power Off button
requires a 2 second hold delay
before the power-down
sequence starts.
VolLimit*
If this feature is enabled, the
X?
maximum initial power-up volume
level will not exceed the level
specified by this command.
0 = audio off, ...,
20 = default value (50% of max.
level), ...,
40 = no limit on audio level.
VolLimit*028
Example: limit power-up volume
to 70% of maximum volume.
AudioMode*
Set the Preamp and amplified
X?
outputs to be either mono or
stereo signals.
1 = mono
2 = stereo (default).