Extron electronics System 5 IP Series User Manual page 62

System switchers with integrated a/v switching, audio amplification, and projector control
Hide thumbs Also See for System 5 IP Series:
Table of Contents

Advertisement

SIS
Programming and Control, cont'd
=
Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800,
X25
7200, 9600, 14400, 19200, 28800, 38400, 57600, or
115200
=
Parity (only the first letter is needed):
X26
Odd
Even
None
Mark
Space
=
Data bits: 7, 8
X27
=
Stop bits: 1, 2
X28
=
Password (minimum length = 4 characters,
X33
maximum length = 12 characters,
no special characters are allowed)
A user password cannot be assigned if no
administrator password exists; the E14 error code
will be returned. If the administrator password is
cleared, then the user password is also removed.
=
Daylight saving time (DST) is a region-specific
X34
1-hour offset that begins in spring and ends in
fall. DST should be turned off in Hawaii,
American Samoa, Guam, Puerto Rico, the Virgin
Islands, the eastern time zone portion of the
state of Indiana, and the state of Arizona
(excluding the Navajo Nation).
0 = off/ignore
1 = USA on – starts on the first Sunday of April
at 2 am and ends at 2 am on the last Sunday of
October. For example, time in California is
GMT -8:00 from April to October and GMT -7:00
from November to March.
2 = Europe on – begins on the last Sunday in
March, ends on the last Sunday in October.
3 = Brazil on – beginning and ending dates vary
from year to year (October through March or
September through February). DST is not used
in equatorial areas.
= Event number, range = 0 - 99
X35
= I/O mode
X40
0 = input
8 = power sensor (triggers when the input pulse
starts/stops) This is for the power sensor
digital input only, on the right 3 pins of the
projector control port.
= Reading password, a string of 4-12 characters
X41
If the switcher is connected via RS-232, the
response is a password.
If the switcher is connected via IP, it responds
with 4 asterisks (****) if a password exists or
with nothing (empty/blank) if no password has
been set.
= I/O state
X43
0 = off
1 = on
= E-mail event number (1 - 64). If used as a response,
X45
this number is represented by 2 digits with
leading zeros.
= E-mail recipient's address (e.g., JDoe@extron.com)
X46
for the person to whom messages will be sent.
5-6
System 5 IP • SIS
Programming and Control
=
For the CR command,
X47
X47
e-mail file to be sent, e.g. 1.eml, 2.eml, ... 64.eml
The filename must be x.eml where x is a number
from 1-999.
The first line of the e-mail file = the subject.
The rest = the body of the e-mail.
For the SM command,
X47
the e-mail file. The SM command overrides
the e-mail file set by the CR command. If
= 0 or is missing (the number is not specified
or the file is not available), the file designated
(set) in the CR command is sent instead.
=
Default name: a combination of the modelname
X49
and the last 3 pairs of the switcher's MAC
address (e.g., SYSTEM5IP-00-02-3D)
= Extended security (password) levels (1-10). If
X51
used as a response,
X51
with a leading zero.
1-10 = extended security levels 1 through 10
=
Connection's security level. If used as a response,
X52
this is returned as 2 digits with a leading zero.
0 = anonymous
1-10 = extended security levels 1 through 10
11 = user
12 = administrator
=
ASCII digit(s) representing the numeric value of
X54
the data element read from the event buffer
(Leading zeros are suppressed.)
=
IR playback file number (0 to 99) (no extension)
X57
=
IR playback function number (1 to 127)
X58
=
IR playback mode
X59
0 = play once
1 = play continuously (send IR command
again with mode = 0 to stop mode 1 playback)
=
Pulse time in 20 ms per count. If this parameter is
X63
missing or = 0, then pulse length = default
(25 = 500 ms). 65535 ms = max. pulse time.
=
Time steps (1-65000) before the IP connection will
X69
time out. Each step (1, 2, 3, ...) equals 10 seconds.
Default = 30 = 300 seconds
If no data is received during the timeout
period, the Ethernet connection wil be closed.
In a response this variable is returned with
leading zeros.
This variable applies only when the unit is
connected via Ethernet. When the unit is
connected via RS-232, only the global timeout
commands apply.
=
A number that is an optional parameter to insert
X70
into the e-mail if the email file contains an
embedded server-side include, "<!--#echo var
|
= WCR
" -->", which is the
CR
command without any parameters.
Use 0 as a placeholder if the optional
used but
isn't needed.
X70
= filename of the
= number (numeral) of
X47
is returned as 2 digits
Esc
is
X47