Jøtul GF 500 DV IPI Installation And Operation Instructions Manual page 32

Direct vent
Table of Contents

Advertisement

139636 GF 500 DV IPI 7/28/14
Remote Transmitter Controls
Temperature Indication Display
With the transmitter in the OFF position, press the
Thermostat Key and the Mode Key at the same
time. The display screen will show the current
room temperature cycling between Fahrenheit and
Celsius indicators each time the keys are pressed
simultaneously. See fig.55.
Pilot Mode
With the transmitter in the OFF position, press the
transmitter Mode key - IPI is the default mode. Fig. 56.
Press the Up arrow to index to the CPI icon and activate
the Continuous Pilot Ignition mode. Fig. 57. Pressing
the Down Arrow Key will return to Intermittent Pilot
Ignition. A single "beep" will confirm reception of the
command.
NOTE: Setting the stove Pilot Mode switch to IPI will
disable remote IPI/CPI switching.
Turn on the Burner
Press the ON/OFF Key on the Transmitter.
The display will show all the active icons. At the
same time, the Receiver will activate the Pilot
Ignitor. First the pilot will ignite, followed shortly
by the burner. A single" beep" from the Receiver will
confirm reception of the command.
Turn off the Burner
Press the ON/OFF Key. The display will show only
the room temperature and icon. At the same time,
the Receiver will deactivate the call for heat and the
burner will shut down. Fig. 58. A single "beep" from
the Receiver will confirm reception of the command.
Remote Burner Control
There are six flame levels available.
With the system ON, and the burner flame level
at maximum, press the Down Arrow Key once to
reduce the flame height by one step. Each time the
Down Key is pressed, the flame will step down until
the burner is finally turned off. Fig. 59.
The Up Arrow Key will increase the flame height
each time it is pressed. If the Up Arrow Key is
pressed while the system is on but the flame is off,
the flame will come on in the High position as in
figs. 60-62. A single "beep" will confirm reception
of the command.
The Auxiliary burner (front flames) is activated by
using the Mode Key to index to the Split Flow icon.
Press the Up Arrow Key to turn it ON. Fig. 63. Press
the Down Arrow Key to turn it OFF. A single "beep"
will confirm reception of the command.
32
Figure 55. Room temperature readings
Figure 56. IPI is the
default position.
Figure 58. Burner shut-down
Figure 60. Flame Level 1.
Figure 62. Flame Level 6.
Figure 57. CPI ON.
Figure 59. Burner OFF.
Figure 61. Flame Level 5.
Figure 63. Split Flame.