Daikin Super Multi Plus E-Series Service Manual page 59

Super multi plus e-series
Hide thumbs Also See for Super Multi Plus E-Series:
Table of Contents

Advertisement

Specifications
Model
Rated Capacity
Front Panel Color
m³/min
Air Flow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Note:
46
CDXS25EAVMT
Cooling
H
8.7 (307)
M
8.0 (282)
L
7.3 (258)
SL
6.2 (219)
W
Steps
5 Steps, Silent, Auto
Removable / Washable / Mildew Proof
A
0.52
W
72
%
62.9
Microcomputer Control
mm
200×700×620
mm
274×906×751
kg
kg
dBA
35/33/31/29
Pa
Both Liquid and Gas Pipes
mm
mm
mm
VP20 (O.D.
The operating sound is based on the rear side suction inlet and the external static pressure 30 Pa.
Operating sound for under side suction inlet : [operating sound for rear side suction inlet] +6 dB.
However, when installation to which the external static pressure becomes low is carried out,
6 dB or more may go up.
Heating
2.5kW Class
8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)
Sirocco Fan
62
0.52
72
62.9
21
29
35/33/31/29
30
φ
6.4
φ
9.5
φ
φ
26 / I.D.
20)
3D052113
SiEN18-622
60Hz 220V
CDXS35EAVMT
Cooling
Heating
3.5kW Class
8.7 (307)
8.7 (307)
8.0 (282)
8.0 (282)
7.3 (258)
7.3 (258)
6.2 (219)
6.2 (219)
Sirocco Fan
62
5 Steps, Silent, Auto
Removable / Washable / Mildew Proof
0.52
0.52
72
72
62.9
62.9
Microcomputer Control
200×700×620
274×906×751
21
29
35/33/31/29
35/33/31/29
30
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
φ
VP20 (O.D.
26 / I.D.
20)
3D052114
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading