4.2.2 Error codes

a) Service error code output
Figure 4-4 Service Error Code Display
b) Error code countermeasures
The following item c) lists all the error codes that the product can display. As for causes and
countermeasures, only the error codes which are newly incorporated in the unit as well as
which require remedies unique to the product are included in the item d).
• Increase the transmission level
Increase service data #2 MENU Parameter No.07 toward 0 (dBm).
• Decrease the transmission level
Decrease service data #2 MENU Parameter No.07 toward -15 (dBm).
• Echo measures
Change the following bit switches of service data #1 SSSW SW03.
Bit 4: 1
Ignore the first DIS signal sent by the other fax machine.
0
Do not ignore the first DIS signal sent by the other fax machine.
Bit 5: 1
Transmit a tonal signal (1850 or 1650 Hz) when the other fax machine
sends a DIS signal.
0
Do not transmit a tonal signal when the other fax machine sends a DIS
signal.
Bit 6: 1
Transmit a 1850-Hz tonal signal when bit 5 is 1.
0
Transmit a 1650-Hz tonal signal when bit 5 is 1.
Bit 7: 1
Transmit a tonal signal before sending a CED signal.
0
Do not transmit a tonal signal before sending a CED signal.
TX/RX No. 5001
Display alternates repaetedly
START AGAIN ##0106
4-15