PC-D320/PC-D340/FAX-L400 Chapter 4: Maintenance and Service
Document
separation roller
White sheet
Platen glass
Do not use tissue. Otherwise, paper dust may stick to the parts or a static
charge may be generated.
Precautions when using Isopropyl alcohol (IPA)
When cleaning with IPA, take care to prevent the IPA from splashing high-
temperature parts. If IPA splashes high-temperature parts, leave for at least
three minutes to allow the IPA to evaporate.
Document
separation guide
Document
pick-up roller
Document
feed roller
Figure 4-1 Cleaning Location 1
4-4
Platen glass cover
Document
eject roller