Rinnai V2532FFUC Manual page 34

Continuous flow water heater
Table of Contents

Advertisement

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S
The remote control for the Integrity V2532C allows the customer to control the
functions of the water heater and to diagnose certain fault conditions.
The Main Controller model MCC-45-4US is intended to be installed in the kitchen or
laundry area where the majority of the hot water is being used.
NOTE: The MCC-45-4US has a temperature setpoint range of 96-180°F.Other
setpoint tempertures must be set through dip switch settings, Contact
Rinnai at 800-621-9419 for dip switch settings.
Before installing the remote control, determine the most convenient location. When
deciding on the best location for the remote control, please consider the following
items:
1) Place the controller out of reach of small children or unauthorised users.
2) Avoid locations where the controller will become hot. (over a stove, near an oven
or a radiant heater.
3) Avoid direct sunlight. (The digital monitor can be difficult to read in direct
sunlight)
4) Avoid areas where the remote can be splashed with cooking water, oil or
sauce.
5) The remote control cable carries low voltage, 12VDC digital.
NOTE: Only one of controller can be connected to one Integrity V2532C water heater.
(i.e. Installations with two controllers will not function properly.)
www.rinnai.us
Remote Control- General