To Suit Models: REU-V1616W..R42 REU-V1616WC..C42 REU-V2020W..R53 REU-V2020WC..C53 REU-V2526W..R70 REU-V2532W..R85 REU-V2532WC..C85 REU-V2532WD..R85PLUS REU-V2532WCD... C85PLUS (Residential and Commercial outdoor unit) ANS Z21.10.3=CSA 4.3 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Remote Control: DC 12 Volts (Digital) Electric Connections Simulation Feedforward and Feedback. Water Temperature Control Minimum Water Pressure: 20 PSI (Rinnai Recommends 30-80 PSI for maximum performance) Water Supply Pressure 150 PSI Maximum Water Supply Pressure Non-Polarized Two Core Cable...
Rinnai will replace the product with a comparable product, at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
Page 4
. Please complete the Warranty registration either online or mail it to Rinnai at the address shown on the card. Receipt of warranty registration by Rinnai will constitute proof-of-purchase for this product.
Error Messages ..............19,20 Maintenance & Service Information ........21,22 Trouble Shooting and Common Questions ........ 23 For Your Safety Read Before Operating ........23 Operating Instructions ..............24 Care & Lime Condition Warning ..........24 Installer’s Instructions ............25-50 Rinnai America W Models...
Ignition is electronic, there is no pilot light. When the hot water tap is off, no gas is used. You save energy and money with the Rinnai Water Heater. The temperature of the outgoing hot water is constantly monitored by a built in sensor. If...
S A F E T Y I S S U E S Depending on the weather conditions and Always check water temperature by hand the length of the pipe between the Rinnai before entering the shower or bath. The Water Heater and the tap in use, there may temperature may have been changed.
NOTE: CHECK LOCAL CODES FOR THE MAXIMUM WATER TEMPERATURE SETTING ALLOWED WHEN USED IN To take control of the Rinnai Water Heater NURSING HOMES, SCHOOL, DAY CARE all hot water taps must be closed. Press CENTERS, AND ALL OTHER PUBLIC the "Priority button"...
A B O U T H O T W A T E R Hot Water Is Dangerous, especially for the young and the elderly or the infirm. The Rinnai Water Heater allows you to precisely control the temperature of your hot water, ensuring safe hot water temperatures.
REMOTE CONTROLLERS IDENTIFICATION MC-91-1US (comes with the unit) MC-100V-1US (optional) BC-100V-1US (optional) The controller(s) for the Rinnai Water Heater allow the customer to control the functions of the water heater and to diagnose certain fault conditions W Models Rinnai America...
Press and hold ‘On/Off’ button for 5 seconds while water heater is OFF. To change back from C to F, please repeat step 1. MUTE To eliminate the beeping sound, press and hold button simultaneously until a ‘beep’ is heard (approximately 5 seconds). Rinnai America W Models...
Thermostat Sound Volume Water Volume Increases or decreases the desired Used to select the voice prompt Used to select Water Smart / Bath water temperature. volume. Fill volumes. Rinnai America W Models...
Page 14
Once the hot water is running, if the set temperature is either too hot or cold, press the buttons until the desired temperature is reached. COLD COLD NOTE: TEMPERATURE CANNOT BE ADJUSTED EXCEPT BETWEEN 98°F AND 110°F WHEN ANY HOT WATER TAP IS OPEN. Rinnai America W Models...
Page 15
IS OPEN. CHECK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. NOTE: Avoid getting water in the speaker as this may cause damage. Rinnai America W Models...
Page 16
Remain by the bath during the filling process. Use a low bath fill volume such as 25 gallons or less. ‘Water Smart / Bath Fill’ button is unavailable with the MSA Controller System. Rinnai America W Models...
Page 17
Kitchen Controller monitor will go out. COMBINING CONTROLLERS AND DELUXE CONTROLLERS Controller and Deluxe Controller can be combined and will function as described in other sections of this manual. Refer to the table on page 18 W Models Rinnai America...
Controllers allow the water temperature to be set from the various locations where they are installed. The temperature selected will be available to all outlets. Below are the combination of Controllers that are offered by Rinnai: Controllers Combination Pattern —...
E R R O R M E S S A G E S The Rinnai Water Heater has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Dispaly of the Remote Controller. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call.
Page 20
Ensure you have at least the minimum flow rate required to fire unit. Ensure turbine spins freely. Measure the resistance of the water flow control sensor. Remote control does not light up but you have 12 VDC at the terminals for controls. Rinnai America W Models...
5) Do not obstruct flow of combustion and ventilation air. In the case of any fault or error message from the Rinnai Water Heater, first turn all hot water taps off. Wait for 5 seconds. Turn the hot water tap back on.
Page 22
The water heater should be cleaned annually. Keep the water heater clear of dust and debris especially in and around burner. Cleaning procedures for the Rinnai Water Heaters are as follows: 1) Turn off and disconnect electrical power. Allow to cool for one hour.
- After I turn off the hot water tap, the fan on the Rinnai Water Heaters continues to run! - The fan is designed to be on for 65 seconds after the flow of water stops.This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit.
If you notice “LC” flashing on the remote key pad, this means the unit is beginning to lime up, and MUST be flushed. Contact a qualified Rinnai service technician to flush the appliance. Failure to flush the appliance when “LC” is flashing, will cause damage to the heat exchanger.
If you are not properly trained, you should not install this unit. The warranty may be voided due to installation by a non-qualified installer. For information on Rinnai Training Courses, call 1-800-621-9419. Warnings ..............26,27 Locating the Vent Terminal ......... 28 Performance Data ............
DO NOT use this water heater for space heating, combination space heating/ domestic water heating, or commercial water heating applications. 3) The Rinnai Water Heater is not suitable for use in pool or spa applications. 4) Install the water heater outdoors only.
Page 27
Toxic chemicals such as those used for boiler water treatment are NOT to be introduced to the portable water used for space heating. The Rinnai Water Heater, if it will be used as a potable water source, must not be connected to a system that was previously used with a nonpotable water heating appliance.
3 feet above if within l n i d l i 10 feet horizontally c i l p o r p t r f i c NOTE: For high altitude installations contact Rinnai at 1-800-621-9419. Rinnai America W Models...
Confer Pressure Relief Valve Solenoid Valve with local building officials before installation. RINNAI WATER HEATERS Domestic Hot Water - Standard Installation 103 International Drive 1 Rinnai Water Heater Peachtree City, Georgia 30269 Rinnai America W Models...
Confer with local building Pressure Relief Valve officials before installation. Solenoid Valve RINNAI WATER HEATERS Domestic Hot Water - Circulation Systems 103 International Drive 1 Rinnai Water Heater with Electric Storage Tank Peachtree City, Georgia 30269 Rinnai America W Models...
Confer Pressure Relief Valve Solenoid Valve with local building officials before installation. RINNAI WATER HEATERS Domestic Hot Water with Circulation 103 International Drive 1 Rinnai Water Heater Peachtree City, Georgia 30269 Rinnai America W Models...
Page 34
I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S RECOMMENDED PIPING FOR FREEZE PROTECTION Vacuum Breaker IMPORTANT! Rinnai With electrical power supplied to a Rinnai water heater, it will not Equipment List freeze in environments as cold as -30ºF, when protected from (Residential and direct wind exposure. Commercial)
I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S RECOMMENDED SCALE FLUSH PROCEDURE RINNAI Water Heater Flush Procedure Disconnect power to Rinnai water heater. Close valves V3 and V4. Rinnai Connect pump outlet hose H1 to service valve V2.
NO FREEZE PROTECTION is available. The installation of auto drain down solenoid valves is optional. However, Rinnai strongly recommends that these valves be installed to prevent damage from freezing in case the normal freeze protection should become disabled. If the valves are not installed then any product damage due to freezing will not be covered by the warranty.
After determining the length of pipe required select the pipe size that will supply the cubic feet per hour of gas required for the input rating of the Rinnai Water Heaters. The formula for figuring the cubic feet per hour required is:...
I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S Gas Piping Notes 1) A manual gas control valve must be placed upon the gas supply line to the Rinnai Water Heaters. A union can be used on the connection above the shut off valve for the future servicing or disconnection of the unit.
2) All soldering materials and piping must be compatible with potable water. 3) Purge the water line to remove from it all debris and air. Debris will damage the Rinnai Water Heaters.
National Electrical Code, ANSl/NFPA 70. In Canada, all electrical wiring to the Rinnai Water Heaters should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the metal parts of the water heater.
3) Turn the manual gas control valve on. STOP!! READ THE SAFETY ISSUES ON PAGES 8 4) Turn on any hot water tap. The Rinnai Water Heater should light and begin heating your water. If the Rinnai Water Heater fails to light 1) DO NOT ATTEMPT TO LIGHT BY HAND.
I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S Remote Controllers- General The remote controls for the Rinnai Water Heater allow the customer to control the functions of the water heater and to diagnose certain fault conditions.
Determine a suitable location for the controller. Make three holes on the wall as shown. Run the cable between the controller and the Rinnai Water Heaters or the controller and the other controller. Remove the face plate from the remote controller.
Page 44
Rem ot e Cont r olle rs I n s ta l l a t i o n to A p p l i a n c e F or m odels : V 2 5 32 WD a n d V 2 5 3 2 WC D 7) Disconnect the power from the Rinnai Water Heater.
If it is determined that the gas pressure needs adjusting, first check the incoming pressure at the test point on the gas inlet. If it is correct follow the adjusting procedure contained in the pouch of the unit EXACTLY. If in doubt call Rinnai 1-800-621-9419.
I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S Schematic Diagram V2532W (R85) & V2532WC (C85) V2020W (R53), V1616W (R42) & V2526W (R70) - Fixed By-Pass *V2020WC (C53) &...