How to use your New Continuous Flow Water Heater Model V2532FFUC (Residential/Commercial indoor unit) ANS Z21.10.3 • CSA 4.3 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WHAT WILL RINNAI DO? Rinnai will repair or replace the product or any part or component that is defective in materials or workmanship*, except as set forth as follows. Rinnai will pay reasonable shipping costs, provided you obtain prior authorization from an Authorized Rinnai Distributor. Rinnai will not pay labor charges associated with the repair or replacement of the product or any part or component.
Remote Control Operation ......... 11 Error Messages ............12 Maintenance & Service Information ....13,14 Trouble Shooting and Common Questions ....15 For Your Safety Read Before Operating....16 Operating Instructions .......... 16,17 Care & Lime Condition Warning ....... 17 Model V2532FFUC www.rinnai.us...
O W N E R ’ S I N S T A L L A T I O N I N F O R M A T I O N IMPORTANT! All Rinnai water heaters MUST be installed by a state qualified or licensed contractor. Failure to comply with your local and state codes pertaining to water heater installations will void the warranty on said water heater(s).
24. The sound (noise) level from the Integrity V2532FFUC is very low. The Integrity V2532FFUC is a very compact power vented device. It saves valuable floor and wall space.
Vent Terminal Do not connect vent to natural draft vents or fireplaces, this unit can only be used with an approved Rinnai/Ubbink vent kit and components. Do not vent unit into other rooms. Vent terminal must be outside. www.rinnai.us...
IN USE displayed on the Digital Monitor. indicator will glow on the remote control. Note: The Rinnai water heater will not provide 140°F hot water instantly at the hot water fixtures. Any cold water existing in the hot water lines must be purged first.
Never use butter, oils or ointment to cover the burn. They may retain the heat. 3) Keep the scalded person warm; Place a blanket around the person. 4) Seek Medical Advice; Call your medical advice hotline and describe the scald, follow their directions. www.rinnai.us Model V2532FFUC...
(i.e. a maintenance room or manager s office. DIAGNOSTIC USE OF REMOTE CONTROL To Display Error Codes To Display Water Flow through water heater To Display Outlet Water Temperature Model V2532FFUC www.rinnai.us...
In the case of any fault or error message from the Integrity V2532C Should overheating occur or the gas supply fail to shutoff, DO NOT ATTEMPT TO SERVICE YOUR Integrity V2532C YOURSELF. Call a Rinnai Authorized Service Technician or call Rinnai at 800-621-9419. Model V2532FFUC www.rinnai.us...
Page 14
MAINTENANCE SUGGESTIONS www.rinnai.us Model V2532FFUC...
- The fan is designed to be on for 65 seconds after the flow of water stops.This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit. Model V2532FFUC www.rinnai.us...
Care of Units Exterior: Lime Condition Warning Signal: MUST Model V2532FFUC www.rinnai.us...
Page 18
Installer’s Instructions All Rinnai water heaters MUST be installed by a state qualified or licensed contractor. Failure to comply with your local and state codes pertaining to water heater installations will void the warranty on said water heater(s). It is the responsibility of the person having the unit installed to ensure the contractor has the proper licences and permits for his state.
Page 19
This manual must be followed exactly. DO NOT Model V2532FFUC www.rinnai.us...
Page 21
Terminals should be so positioned as to avoid products of combustion entering openings into buildings or other flues or vents. Vent/Air Intake Terminal positions - MINIMUM dimensions. Model V2532FFUC www.rinnai.us...
Page 24
V2532FFUC Water Heater Commercial Hot Water with Recirculation 1 Integrity V2532FFUC - Preferred Method of Installation V2532WC www.rinnai.us Model V2532FFUC...
Page 25
Dip switch # 1 is located in the top row of dip switches, 1 through 8 on the PC board. See the diagram below to identify the proper switch. If you do not understand the following information, contact Rinnai at 1-(800)621-9419 for assistance. Do not alter dip switch number 1 before using formula, to determine the proper setting.
Page 26
Vent/Air Intake for Continuum V2532C Hot Water Systems The only vent/air intake systems approved for use with this appliance by CSA are the Rinnai/Ubbink vent system or the Heatfab Saf-T Vent SC vent system. The vent system must vent directly to the outside of a building and use outside air for combustion as indicated in the diagrams below.
Page 27
(table assumes 11 inches of water column pressure at the inlet, .5 inch drop) Nominal Length of Pipe in Feet Iron Pipe Size Inches 100 125 162 146 1071 307 275 1-1/4 2205 1496 1212 1039 630 567 Model V2532FFUC www.rinnai.us...
Page 28
Natural Gas: Propane Gas: 1 3 . 5 WARNING: Conversion of this unit from natural gas to propane or propane to natural gas CANNOT be done in the field. Caution: www.rinnai.us Model V2532FFUC...
Page 29
WARNING: DO NOT reverse the inlet and outlet (cold and hot water) connections on the unit. This would cause the Integrity V2532C to operate dangerously or not at all. Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves Model V2532FFUC www.rinnai.us...
Page 30
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify correct operation after servicing. www.rinnai.us Model V2532FFUC...
Page 31
I N S TA L L E R S I N S TA L L AT I O N I N S T R U C T I O N S Wiring Diagram Model V2532FFUC www.rinnai.us...
Page 32
I N S TA L L E R S I N S TA L L AT I O N I N S T R U C T I O N S Wiring Diagram www.rinnai.us Model V2532FFUC...
Page 33
6) Turn the electrical power to the unit on. 7) Turn on any hot water tap. 8) If the unit still fails to light, turn off the electricity and gas to the unit and call Rinnai 1-800-621-9419. Model V2532FFUC www.rinnai.us...
Page 34
NOTE: The MCC-45-4US has a temperature setpoint range of 96-180°F.Other setpoint tempertures must be set through dip switch settings, Contact Rinnai at 800-621-9419 for dip switch settings. Before installing the remote control, determine the most convenient location. When deciding on the best location for the remote control, please consider the following items: 1) Place the controller out of reach of small children or unauthorised users.
Page 35
PCB. 11) Secure the control cable using the clamp provided. 12) Replace plastic cover over PCB and then replace the cover of the Integrity V2532C. Model V2532FFUC www.rinnai.us...
Page 36
NOTE: The pressure may be low due to too little flow, too high an incoming temperature, and/or undersized gas piping. Examine these areas before determining that the pressure needs to be adjusted. Contact Rinnai before adjusting manifold pressures at 1-800-621-9419. Failure to contact Rinnai, could void units warranty.