Page 2
Not suitable as a spa or swimming pool heater. Rinnai continuous flow internal water heaters (‘i’ models) must be installed with an approved Rinnai flue system. Appliance must be installed, commissioned and serviced by an authorised person, being in New Zealand a licensed gasfitter, in accordance with these instructions and all applicable local rules and regulations.
Before installation Appliance location General installation information Flued (internal) water heaters Water delivery temperature Connections and fittings Dimensions: VT and HD models Dimensions: EF models EF250 models: Earthing the unit EF models: Condensate drain Controllers - general information Controllers - Universal (Compact) Controllers - Kitchen Deluxe Controllers - Bathroom Deluxe Controllers - communication cables...
For Rinnai continuous flow water heaters used in solar installations, refer ‘Recommended Solar System Layout’. EF models are heavy The Rinnai Infinity EF models are 32 kg. Please use care when lifting and seek assistance if required. Applicable models These installation instructions apply to the following Rinnai continuous flow water heaters.
This appliance MUST be used with (as shown), and not a partial the appropriate Rinnai flue system. Where possible, install the obstruction. A partial obstruction heater in a sealed closet so...
Page 6
Alternatively, multiple appliances can be strategically placed to serve different outlets. Contact Rinnai for further information. An AC 230 V, 10 Amp, earthed power point must be provided adjacent to the appliance. For outdoor installations, this power point must be weatherproof.
Rinnai with AS/NZS 3500. All hot water to the walls, in accordance with and we will provide you with the pipe work should be insulated to AS/NZS 5601.1.
Flued (internal) water heaters This water heater must be fitted with the appropriate Rinnai flue system. The chart below highlights the maximum flue length and number of bends. It also shows the difference between a short and long flue—this is important if changing settings (DIP switches).
AS/NZ3500.4 a Temperature Limiting Device (TLD), such as a Tempering Valve may be required (even if the appliance is set to 55 °C or less). For these types of applications contact Rinnai. Requirements for Rinnai continuous flow units installed without controllers 55 °C > 55 °C >...
Dimensions: VT and HD models Dimensions table (mm) Width Depth 235~275 Height - unit Height - including brackets Hot water outlet (from wall) 91~131 Hot water outlet (from centre) Cold water inlet (from wall) 70~110 Cold water inlet (from centre) Gas connection (from wall) 99~139 Gas connection (from centre)
Removing the cover and earthing the unit For the Rinnai condensing continuous flow water heaters (EF250 & EFi250), the earthing screws are located under the side trim, refer image below. First remove the trim and then the earthing screws before lifting off the cover.
EF models: Condensate drain Maximum length and changes of Joining of condensate drain lines The Rinnai Infinity EF water heaters direction greater than 45° generate condensate continuously Condensate drain lines from at a rate of up to five litres per hour...
(BC-100V) Extension cabling is available Only one controller can be set as an accessory from Rinnai. to deliver 55 °C, this cannot be a Alternatively, a two core sheathed Bathroom Deluxe controller. (double insulated) flex with a...
Controllers - Universal (Compact) Fitting the Universal (Compact) 6. Remove protective plastic controller from the controller face as shown (Fig. 4) and replace the Determine the most suitable face plate. position for the controller. Optional programming of the 2. Drill three holes as shown (Fig.
Controllers - Kitchen Deluxe Installation Determine the most suitable position for the controller. 2. Use the wall mounting bracket as a template to mark and drill three holes, locating the cable access hole as shown. 3. Fix the mounting bracket to the wall using the appropriate fixings.
Controllers - Bathroom Deluxe Installation Outline of Water Controller Determine the most suitable position for the controller. 2. Mark and drill three holes, locating the cable access hole Securing as shown (Fig.1). Screw Ø20 Cable Access 3. When running a cable through the access hole ensure the Fig.1 connector end of the cable...
Up to two cables can be connected to the cable connector at the controllers water heater. Extension cables are Repeat steps 1-3 for available from Rinnai. Alternatively connecting up to two two core sheathed (double controllers. insulated) flex with a minimum cross sectional area of 0.5 mm...
Recommended solar system layout Rinnai continuous flow water heaters configured for solar systems produce hot water at 75 °C and are not suitable for use with water controllers. The household water supply MUST be protected by a suitable tempering valve.