Version 7.06 - Bosch D9412GV2 User Manual

Table of Contents

Advertisement

D9412GV2/D7412GV2
prompts are set to 0000, which is treated as
if set to the default value of 7700.
RPS Port Number: The Base Port Number
prompt was renamed RPS Port Number to
distinguish it from the Enhanced
Communication Path Port Number prompts.
This prompt continues to provide the
destination port for network RPS sessions
initiated by the control panel.
Anti-substitution Enhancement: The anti-
replay, or anti-panel-substitution, feature was
enhanced to allow simultaneous multiple
enhanced communication paths. Previously,
only one path could be enabled when the
EnableAntireplay prompt was set to Yes.
Now, each destination path has its own Path
#AntiReplay prompt, and multiple paths can
be enabled.
When RPS v5.7 or later, or GV2AUX
v1.03 or later, sends data to a
D9412GV2 or D7412GV2 control
panel running v7.06 or earlier, use
the Path 1AntiReplay prompt to
enable the Anti-Replay feature.
Time Sync Enhancements: The Time Sync
feature is used by the D6600 receiver to
update the minutes of the hour in the control
panel clock to keep it synchronized with the
time at the central station. This feature was
updated to manage the control panel clock
adjustments over a period of time instead of
simply jumping to the new time. This
enhancement allows consistent execution of
Skeds at their intended times. When a
TimeSync adjustment is in process, the
Time/Date idle text display is modified with a
'+' or '-' sign to indicate control panel time is
increasing or decreasing to match the target
time. When a TimeSync adjustment
completes, the control panel sends a Time
Change event as User 254. This feature is
enabled and disabled at the D6600 receiver,
and cannot be controlled by the control
panel.
F01U003637-06
D9412GV2/D7412GV2 Release Notes for Version 7.09
If the control panel is configured to
send to multiple D6600 receivers
using enhanced communication
paths, enable Time Sync in only one
receiver account.
Local AC Failure Annunciation: Changes
were made to delay the keypad AC Failure
display by the amount of time programmed in
AC Fail Display prompt after the main line
AC is lost. The same delay is used to hold off
clearing the display when the AC returns. The
AC failure report and AC failure relay still
follow the delay programmed in AC Fail
Time.
2.4

Version 7.06

Changes allow RPS workstations located on a
private network behind a router or firewall to
communicate with control panels outside of that
network. No special router or firewall settings
are required. The control panels support Port
Address Translation (PAT) for networks that
require it.
RPS must be version 5.5 or later to
support this feature.
If firewall software is installed on the
RPS workstation, special software
firewall settings might be required to
allow outgoing traffic. Refer to your
firewall software for configuration
information.
Any DX4020 or D9133TTL-E used for
enhanced communication to a central
station receiver, or with RPS over a
network, must be configured to use
Datagram Mode 2 when the control
panel firmware is version 7.06 and
later. Refer to the DX4020 Operation
and Installation Manual (P/N:
F01U045288) or the D9133TTL-E
Installation Guide (P/N: 4998122717)
for configuration instructions.