Vertical Venting With Two (2) 90 Elbows; Vertical Venting With Three (3) 90 Elbows - FPI P36D-NG1 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Hide thumbs Also See for P36D-NG1:
Table of Contents

Advertisement

INSTALLATION
One 90
o
elbow = Two 45
Option
V
H
A)
0' Min.
2' Max. 1' Min.
B)
1' Min.
4' Max. 3' Min.
C)
2' Min.
5' Max. 4' Min.
D)
3' Min.
6' Max. 5' Min.
E)
4' Min.
7' Max. 6' Min.
F)
5' Min.
8' Max. 7' Min.
Lengths do not include elbow indicated.
One 90
elbow = Two 45
o
Option
V
H + H1 V + V1
A)
0' Min.
2' Max. 2' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
3' Max. 4' Min.
D)
3' Min.
4' Max. 6' Min.
E)
4' Min.
5' Max. 7' Min.
F)
5' Min.
6' Max. 8' Min.
G)
6' Min.
7' Max.
H)
7' Min.
8' Max. 10' Min.
Lengths do not include elbow indicated.
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
VERTICAL VENTING WITH TWO (2) 90
o
elbows.
V + V1
With these options, max. total
pipe length is 30 feet with min.
of 7 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
VERTICAL VENTING WITH THREE (3) 90
elbows.
o
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
9' Min.
required.
ELBOWS
O
V1
ELBOWS
O
V1
H1
V
H
V
H
29