Guide-Assy-Retard - Oki MC760 Maintenance Manual

Hide thumbs Also See for MC760:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
4.2.34 Guide-Assy-Retard
(1) Remove the eight claws and remove the Guide-Retard(sub) ① .
(2) Remove the Cover-Retard(ADF) ② .
(3) Remove the Frame-Assy Retard ③ and remove the spring Retard ④ .
(4) Remove the Lever-Hopping ⑤ and the spring-Hopping ⑥ .
(5) Remove the Photo-coupler ⑦ and remove the cable (conn cord AMP3P-
JST4P) ⑧ .
Claw
Claw
Claw
45376001TH Rev.1
Claw
Claw
4.2.35 Flatbed-Unit
(1) Remove the five screws (black, No:42932706) ① and remove the cover-
Bottom ② .
(2) R e m ove t h e s c r ew ( s i l ve r, N o : 4 2 9 2 0 4 0 6 ) ③ a n d r e m ove t h e p l a t e -
stopper(OP) ④ .
(3) Remove the two screws (black, No:PB4083-5670P013) ⑤ and remove the
cover-OP ⑥ .
(4) Remove the screw (black, No:42932708) ⑦ and remove the Handle-
scanner(S) ⑧ .
(5) Rotate the OP-panel-unit ⑨ 90 degrees.
(6) Remove the two screws (silver, No:42920406) ⑩ .
(7) Remove the screw (silver, No:42920406) ⑪ and remove the clamp-cable ⑫ and
remove the OP-panel-unit ⑨ .
Attention of assembly for direction of plate-stopper(OP)
(for finisher model)
(for without finisher model)
4. Component replacement
97 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc770Mc780Mps3537mcMps4242mc

Table of Contents