Oki Data CONFIDENTIAL
4.2.13 Top cover
(1) Remove the top cover Assy. (See section 4.2.12)
(2) Remove fifteen screws(black, No:42932708) ① , and remove the top cover ② .
(3) R e m o v e t h e s c r e w ( s i l v e r , N o : 4 2 9 2 0 4 0 6 ) ③ , r e m o v e t h e t w o
screws(silver,No:42920420) ④ and remove the Head Cable ⑤ .
45376001TH Rev.1
4.2.14 Frame Assy Top Front
(1) Remove the right side cover. (See section 4.2.3)
(2) Remove the plate shield. (See section 4.2.9)
(3) Remove the connector of Frame Assy Top Front.
(4) Remove the two screws (silver, No:42920406) ① ,disengage the claws(3 places)
on the Frame Assy Top Front ② , and remove the Frame Assy Top Front ② .
Claw
4. Component replacement
81 /