Oki MC760 Maintenance Manual page 155

Hide thumbs Also See for MC760:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Error code
Cause
C5A1
Read/write
error of
the engine
EEPROM is
detected.
C940
Engine control
logic has an
error.
F031
Duplex unit for
other model is
detected.
F033
2nd tray for
other model is
detected.
F032
3rd tray for
other model is
detected.
C96A
High voltage
power supply
interface error.
C0A2
Low voltage
power supply
fan error
CE51
Environment
humidity is
abnormal./
Humidity
sensor is not
connected.
CE50
Environment
temperature
is abnormal.
45376001TH Rev.1
Error details
Remedial measure
Turn off the power
Does this error recur?
Yes
of the printer and
back on.
Replace the PU
board.
Turn off the power
of the printer and
back on.
Does this error recur?
Yes
Replace the PU
board.
Is the Duplex unit for that
No Install the correct
specific model installed?
duplex unit.
Is the 2nd tray for that specific
No Install the correct
model installed?
2nd tray.
Is the 3rd tray for that specific
No Install the correct
model installed?
3rd tray.
Is the cable connecting the PU
No
Re-connect them
board to the high voltage unit
normally.
connected normally?
Yes
Check for defective
Have you checked defective
contact of the high
contact of contactor points?
voltage system.
No
Replace the high
voltage power
Note)
supply.
No
Check for sure
Is the fan (bottom right of the
connection of the
front) of the low voltage power
supply block working?
fan connector.
Yes
Replace the PU
board.
Is the fan connector connected
No
Replace the fan
normally?
motor.
Yes
Turn off the power
of the printer and
back on.
Does this error recur?
Yes
Replace the Board
MFH.
Turn off the power
of the printer and
back on.
Does this error recur?
Yes
Replace the Board
MFH.
Error code
Cause
CE52
Dew
This error can easily occur
condensation
when a printer is brought in to
of the printer
indoor from outdoor.
is detected.
Leave the printer for 2 hours
or half day under room
temperature, and turn on the
power again.
Does this error recur?
C0A1
Fuser exhaust
Is the fan connector connected
fan error
normally?
Does this error recur?
C0A5
ID cooling fan
Is the fan connector connected
error
normally?
Does this error recur?
C0A6
Duplex
Fan error inside the Duplex unit.
FAN Alarm
Caution
Does the error recur when the
power is turned off once and
back on?
Does the error recur when the
power is turned off once and
back on?
CE82~
LED head
Is the LED head connected
CE85
detection
normally?
error
(CE82=Y,
CE83=M,
Is the LED HEAD fuse brown?
CE84=C,
Does this error recur?
CE85=K)
CE7A
ID Up/Down
Is the ID unit caught by anything
position
when it is removed and re-
detection
installed?
error
Does this error recur?
7. Troubleshooting and repair procedure
Error details
Remedial measure
After leaving a
printer under room
temperature, turn
on the power
again.
Yes
Replace the Board
MFH.
No
Re-connect it
normally.
Yes
Replace the fan
motor.
No
Replace the PU
board.
No
Re-connect it
normally.
Yes
Replace the fan
motor.
No
Replace the PU
board.
Check if the Duplex
unit is installed
normally or not.
Check if the fans
Yes
are installed
normally or not.
Replace the fan.
Yes
No
Install the LED
head unit normally.
Yes
Check the LED
HEAD fuse.
Yes
After checking fuse
No
Turn on the power
again.
Yes
For the method of
checking the LED
head unit fuse,
refer to section 7.6.
Yes
Re-install the ID
unit.
No
Turn on the power
again.
Yes
Replace the high
voltage power supply.
154 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc770Mc780Mps3537mcMps4242mc