Free Objects - Siemens SINAMICS G120 Operating Instructions Manual

Inverter with the cu250s-2 control unit (vector)
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

OD
Subind
Object name
index
ex
(hex)
(hex)
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
7.8.2.2

Free objects

You can interconnect any process data objects of the receive and transmit buffer using
receive and transmit double words.
● Scaling the process data of the free objects:
The "SINAMICS parameters" column shows the parameter numbers assigned in the
converter. The assignment applies to the case in which an object which is not mapped in any
PDO is to be accessed via SDO.
OD index (hex) Description
5800 ... 580F
16 freely-interconnectable receive process
data
5810 ... 581F
16 freely-interconnectable transmit process
data
5820 ... 5827
8 freely-interconnectable receive process data
5828 ... 582F
Reserved
5830 ... 5837
8 freely-interconnectable transmit process data I32
5828 ... 582F
Reserved
Converter with the CU250S-2 Control Unit (vector)
Operating Instructions, 06/2013, FW V4.6, A5E31759476B AB
– 16-bit (word): 4000 hex ≙ 100%
– 32-bit (doubleword) 4000000 hex ≙ 100%
– For temperature values: 16-bit (word): 4000 hex ≙ 100° C
– For temperature values: 32-bit (doubleword): 4000000 hex ≙ 100° C
7.8 Communication over CANopen
SINAMICS
Data type
parameters
p8737.2
U32
p8737.3
U32
Data type
Default
per PZD
values
I16
0
I16
0
I32
0
0
Configuring the fieldbus
Predefined
Can be
connection
read/
set
written
0
r/w
0
r/w
Can be read/
SINAMICS
written
parameters
r/w
r8745[0 ... 15]
r
r8746[0 ... 15]
r/w
r8747[0 ... 7]
r
r8748[0 ... 7]
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents