9.13 Scanner set-up menu options

The Scanner Set-up menu enables you to configure the performance and behavior of your radar scanner.
Function
Timed Transmit Set-up
Tune Adjust
EBL Reference
170
Description
This menu item contains a sub-menu that enables you to adjust the timed transmit
options:
• Timed Transmit
• Transmit Period
• Standby Period
This menu item allows you to fine tune the radar scanner's receiver for maximum
returns on the display. Raymarine recommends that this function is set to Auto.
If you set this function to Manual and adjust the setting shortly after powering
up the radar scanner, you should adjust it again approximately 10 minutes after
powering up the scanner, as the required setting will change after the magnetron
has warmed up.
The measurement point used for reference when measuring distances using
Electronic Bearing Lines (EBLs) and range rings in the chart application. The
options are Relative to ships heading or referenced to the compass is degrees
Magnetic — True as selected in Bearing Mode.
Options
Timed Transmit
• On
• Off
Transmit Period
• 10 Scans
• 20 Scans
• 30 Scans
Standby Period
• 3 minutes
• 5 minutes
• 10 minutes
• 15 minutes
Man
• Auto
• Man 0% — 100%
• Relative
• Mag-True