1-5-25

SMDR Valid Call Time Assignment

General Description
Use this Memory Block to assign the minimum call time before the Station Message
Detail Recording (SMDR) outputs a record of the outgoing CO/PBX call.
Display
D a t a
N o .
2 5 : S M D R
T I M E
Programming Procedures
1 Go off-line.
B E
2 Press LK1 + LK5 +
3 Use the dial pad to enter data.
Minimum time assignment is 000 sec.
G
Time assignment can be set from 000~099 sec. in increments of 10.
4 Press
to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
1-1-05
Start Time Selection
1-5-13
Printer Connected Selection
___________________________________________________________________________________
Programming Manual
S e t t i n g
D a t a
T i t l e
T I M = 0 4 0 s
D I S P L A Y
to access the Memory Block.
E
to go back on-line.
Document Revision 1
System Mode
Submode
Data No.
PC Programming
Default Values
040 seconds
1
5
25
+AS
2 - 157