Electrical Connection; Water Connection; Drain Connection - Hobart AM900 Installation And Operation Instructions Manual

Glass and dishwashers
Table of Contents

Advertisement

instAllAtion
dE
GB
F
nl
A
6
2.3

ElEctRicAl connEction

Must be carried out by an authorized technician according
to the local and national codes.
The electrical supply shall comply with the name-plate data.
Line fuses and cable cross section shall comply with the requirements.
A cut-off device shall be provided to connect the supply cord (isolating
switch or accessible plug device).
According to EN 60 5 the appliance must be connected to an equipotential
conductor. The connecting screw (
2.4

wAtER connEction

Must be carried out by an authorized technician according
to the national and local codes.
the machine must be operated with potable water.
For water with an extremely high mineral content an external
demineralisation is strongly recommended.
Machines without softener: Connect to soft and if possible warm
water (up to 4° Clark = 0.5 mmol/l, max. 60°c).
Machines with softener: Connect to warm water (max. 60°c) if
possible.
Line flow pressure 0.5 – 10 bar.
important: the line flow pressure must not be less than 0.5 bar.
if the line flow pressure is above 10 bar provide pressure reducer
at source.
Connect the union nut "A" (
shut off valve.
Do not kink or cut the supply hose.
If an extended supply hose is required, use one of the same
specifications as the original.
2.5

dRAin connEction

Connection between machine and site drain must not exceed max.
height of 0.75 m.
Do not place the drain hose loosely on the floor (the hose could be
rubbed through). Fix it at site!
Do not kink the drain hose.
) is located beside the cable inlet.
/
") of the water supply hose to the site

4
AG-1590-A-09-08