5
stARt-up
AG-1590-A-09-08
5.1
dEtERGEnt / RinsE Aid
Use only commercial detergent and rinse aid. please pay attention to
the manufacturers safety instructions.
the dosing pumps can operate to a maximum head height
of 1.5 m. do not confuse the containers !
5.1.1
dEtERGEnt
do not use any acidic detergent products with the built-in detergent
pump! (the ph-value has to be higher than 7.)
–
Place the suction hose into the external detergent container.
Fill the suction hose according to chapter 5.2.
5.1.2
RinsE Aid
Place the suction hose (blue marking) into the external rinse aid
–
container. Fill the suction hose according to chapter 5.2.
5.1.3
chAnGinG thE typE oF dEtERGEnt / RinsE Aid
–
Before changing to a different product type (even from the same
supplier), the suction hoses must be rinsed thoroughly with fresh
water (procedure as described under 5.).
Otherwise, the mixing of different types of chemicals will cause
crystallisation, which may result in a malfunction of the dosing pump.
5.2
pRiMinG thE suction hosEs
–
We recommend the manual hose priming as follows.
AttEntion:
the machine has to be switched off.
–
open the hood.
–
Push stop button
upper display
➄
Push program button repeatedly, until "d" is displayed.
–
close the hood.
–
In the upper display appears "sF1", in the lower one "0".
➂
and program button
➁
shows "ch1".
simultaneously until the
9
dE
GB
F
nl