pREViEw oF tEMpERAtuREs

dE
GB
F
nl
9

FAults

codE
possiBlE cAusE
Al
Drain hose blocked.
hEi
Rinse booster heating defective.
d 0
OPTION
External demineralisation cartridge depleted.
sAl
Salt deficiency
(only with built-in softener).
The service indicator
codE
possiBlE cAusE
Fil
Shut-off valve is closed.
Fill valve or fill system defective.
siE
Tank strainer not correctly positioned.
ul
Drain hose blocked.
Fill system or drain system defective.
F01
Temperature probe "rinse booster" defective.
F02
Temperature probe "tank" defective.
F03
Pressure transmitter "rinse booster" defective.
F04
Pressure transmitter "tank" defective.
othER indicAtions
Moving light point in the upper display:
codE
cAusE
. .
.
Softener regeneration active (only with built-in
softener).
14
Press and hold (3 seconds) the program button
temperatures (°c) are displayed (top = rinse, bottom = wash).
The indicators go out 10 seconds after releasing the program button.
Permanent temperature display can be activated on request by the
service technician.
According to the fault, an error code will be shown in the upper
display
please report the error code to the service technician.
is illuminated and:
(see table below).
MEAsuREs
Restart drain cycle. Clean drain hose if necessary.
Call the after sales service.
Replace cartridge.
Refill the softener with granular regeneration salt.
MEAsuREs
Open shut-off valve at site and switch on machine again.
Call the after sales service.
Put strainer correctly in place.
Clean drain hose and restart drain cycle.
Call the after sales service.
Call the after sales service.
Call the after sales service.
Call the after sales service.
Call the after sales service.
MEAsuREs
None.
until the actual