The GPS Chart Plotter reads the AIS NMEA message VMD, type 1, 2, 3 and 5 for AIS Class
A and type 18, 19, 24 for AIS Class B. Select the used port and transmission speed by
following the procedure:
The CP390i has to be setup to be able to receive NMEA information from the AIS receiver.
1. Press [MENU], move the ShuttlePoint knob to highlight SETUP MENU and press [ENT].
2. Move the ShuttlePoint knob to highlight ADVANCED SETUP and press [ENT] or move
the ShuttlePoint knob to the right.
3. Move the ShuttlePoint knob to highlight IN/OUT CONNECTIONS and press [ENT] or
move the ShuttlePoint knob to the right.
4. Move the ShuttlePoint knob to highlight PORT4 INPUT (or other Port the AIS is
connected to) and press [ENT] or move the ShuttlePoint knob to the right.
5. Move the ShuttlePoint knob up/down to select AIS 38400 and press [ENT] or move the
ShuttlePoint knob to the right.
2.4.2

CPF390i Connection Table

12VDC Power
Pin Wire Color Description
1
Black
Battery Ground &
Common for
NMEA devices*
2
Red
Battery Positive
3
Green
Port3 Input
4
Blue
Port1 Input
5
Brown
Port1 Output
6
Gray
Port2 Input
7
White
Port2 Output
8
Yellow
Port3 Output
*NOTE
RS232 not opto-isolated electrical interface.
2.4.3

CPF390i Connections

2.4.3.0 DC Power Connection
CPF390i
Transducer
CP390i and CPF390i
Connection Example
Connect to Battery Ground and
and signal ground
Connect to Battery Positive
Connect to Output of NMEA devices*
Connect to Output of NMEA devices*
Connect to Input of NMEA devices*
Connect to Output of NMEA devices*
Connect to Input of NMEA devices*
Connect to Input of NMEA devices*
Optional WAAS GPS
antenna
Additional Comments
Default is NMEA0183
Default is NMEA0183
Default is NMEA0183 with GGA, GLL, RMC,
XTE, DBT, DPT, MTW, VHW sentences
Default is NMEA0183
Default is NMEA0183 with GGA, GLL, RMC
and XTE sentences
Default is NMEA0183 with APA, APB, BOD,
GGA, GLL, RMC and BOD sentences
Red
Black
PWR & ACC 1 Cable
Switch
-
+
2A
Battery
Fuse
10-35Vdc