02 Stop:
Zn List
No List
02 Stop:
Zn Typ
Not Used
02
A EV ZL ZT
STT 0
0
0
00
02
A EV ZL ZT
STP – –
0
00
Example of Output
Relay Programming
00 = Not Used
01 = Entry/Exit #1
02 = Not used
03 = Perimeter
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry
31 = End of Exit Time
32 = Start of Entry Time
If a zone list will be used to STOP, or restore, the relay action, enter the zone list
(ZL) number 1, 2, or 3 (to be programmed in 81 mode). If not used, enter 0.
0
Press the [ ] key to continue.
If a zone type or system operation will be used to STOP the relay action, enter
the appropriate two digit code (see the "ZT" choices listed above). If not, enter
00
00.
Press the [ ] key to continue.
This screen again displays a summary of the current relay START
programming.
Press the [ ] key to continue.
This screen again displays a summary of the current relay STOP programming.
Press the [ ] key to continue.
The display then returns again to the first screen so that the next relay number
to be programmed can be entered, or enter [0][0] to end relay programming.
Previously entered data can be reviewed by pressing [#] [8] [0]. After the relay
number is chosen, press [ ] to go to the next screens. This is a review mode
only, and data cannot be changed.
A lamp is to be turned on when any one of 3 specific zones are faulted or
when any 24-hour auxiliary zone is disturbed. We want to turn off the
lamp manually without affecting the arming status of the system.
In field 80 we choose Output Relay 01 and program the Action (A) to be "2"
(Close and stay closed). The Event we are looking for to start the relay action
is a fault, so we will program "2" in (EV). We will use Zone List 1 for the 3
specific zones, so we will program "1" in (ZL), and we will program these 3
zones in field 81's Zone List 1.
The second condition for turning on the indicator is triggering a 24-hour aux.
zone (Zone Type 08), so we will program (ZT) as "08".
To stop relay action and turn off the indicator, we do not want to use a restore
of any zone, so we will program a "0" for the " Restore of" Zone List (ZL). To
choose a manual entry of User Code + [#] + [7] to turn it off, we will program
(ZT) as "34" (see "Choices for System Operation" in the table above).
If no other relay is to be programmed we go to field *81 and program the 3
specific zones in Zone List 1.
Press
81. (Zone Lists for Output Relays). This interactive menu mode is
applicable only if you have programmed 80 mode.
Refer to the Programming Form worksheet for
Programming Guide.
CHOICES FOR ZONE TYPES
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
CHOICES FOR SYSTEM OPERATION
33 = Any Burglary Alarm
34 = Code + # + 7 Key Entry
36 = At Bell Timeout**
38 = Chime
**Or at Disarming, whichever occurs earlier.
– 48 –
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
39 = Any Fire Alarm
40 = Bypassing
41 = AC Power Failure
42 = System Batt. Low
58 = Duress
81 Mode in the separate