First Alert FA142C Installation Instructions Manual page 87

Security systems
Hide thumbs Also See for FA142C:
Table of Contents

Advertisement

FA550KP
REMOTE KEYPAD
4281L, 4281M, 4281H
RF RECEIVERS
(5700 System)
and
5881L, 5881M, 5881H
RF RECEIVERS
(5800 System)
5800TM
TRANSMITTER
MODULE
used with 5827BD
Wireless 2-Way Keypad
4204
RELAY MODULE
4219
WIRED EXPANSION
MODULE
4229
WIRED EXPANSION/
RELAY MODULE
FA4285
PHONE MODULE
7720PLUS/7820
LONG RANGE RADIO
1. Physical:
5-1/16" W x 6-3/8" H x 1-3/4" D (129mm x 162mm x 45mm).
2. Electrical:
Voltage Input: 12VDC; Current Drain: 140mA.
3. Interface Wiring: Same as FA210KP.
1. Physical:
7-3/8" (188mm) W x 4-3/8" (112mm) H x 1-7/16" (37mm) D.
2. Electrical:
Voltage Input: 12VDC; Current Drain: 35mA.
3. Interface Wiring: Same as 4127.
4. Range:
200ft (60m) nominal indoors from wireless transmitters (the
actual range to be determined with system in TEST mode).
5. Zones:
(With the FA142C)
4281L: accepts up to 4 transmitters.
4281M or 4281H: accepts up to 8 transmitters.
5881L/5882L*: accepts up to 8 transmitters.
5881M: accepts up to 16 transmitters.
5881H/5882H: accepts up to 30 transmitters.
1. Physical:
2-1/4" W x 4-1/8" H x 7/8" D (57mm x 105mm x 22mm).
2. Electrical:
Voltage Input: 12VDC; Current Drain: 20mA.
3. Interface Wiring: Same as FA210KP.
1. Physical:
6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm).
2. Electrical:
Voltage Input: 12VDC; Current Drain: 15mA (Relays off).
3. Interface Wiring: Same as FA210KP.
4. Four Output Relays:
1. Physical:
6-1/2" W x 4-1/4" H x 1-1/4" D
2. Electrical:
Voltage Input: 12VDC; Current Drain: 35mA
3. Interface Wiring: Same as FA210KP.
4. Four Output Relays:
1. Physical:
6-1/2" W x 4-1/4" H x 1-1/4" D
2. Electrical:
Voltage Input: 12VDC; Current Drain: 35mA (Relays off)
3. Interface Wiring: Same as FA210KP.
4. 8 EOLR Loops (A–H):
5. Two Output Relays:
1. Physical:
6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm).
2. Electrical:
Voltage Input: 12VDC; Current Drain: 160mA.
3. Device Address: Permanently set to address 4.
4. Interface Wiring: See FA4285 PHONE MODULE section.
5. Telephone Line Connections: See FA4285 PHONE MODULE section.
1. Physical:
8-1/2" W x 9-1/2" H x 1-3/4" D (216mm x 242mm x 45mm).
2. Electrical:
Voltage Input: 12VDC; Current Drain: 150mA.
3. Device Address: Set to address 3.
4. Interface Wiring: Same as FA210KP.
– 87 –
Note: 10-7/8" (277mm) H with antenna.
SPDT Contacts.
Rating:
2A max at 28VDC/AC.
(169mm x 108mm x 32mm)
SPDT Contacts, Rating: 2A max at 28VDC/AC
(169mm x 108mm x 32mm)
Loop A can be set for fast (10–15msec) response
to an open.
SPDT Contacts; Rating: 2A max at 28VDC/AC
180mA (Relays on).
100mA (Relays on)