Iq 5 Light Image - Xerox WORKCENTRE PE 220 Service Manual

Workcentre
Hide thumbs Also See for WORKCENTRE PE 220:
Table of Contents

Advertisement

IQ 5 Light Image

Description
The printed image is light, with no ghost.
Workcentre PE 220
Check and Cause
1. Develop roller is contaminated
when the print cartridge is almost
consumed.
2. Ambient temperature is below
than 10°C.
3. Check shading profile.
4. Bad contact caused by the toner
contamination between the high
voltage terminal in the HVPS and
the one in the set.
5. Abnormal output from the HVPS
can be caused by contamination
11/05
Image Quality
Solution
1. Install a new print cartridge,
2. Wait 30 minutes after printer is
powered on before you start print-
ing.
3. Redo shading profile in the Tech
mode.
4. Clean the contaminated area.
5. If necessary, install a new HVPS,
PL
1.
PL
1.
3-7