Wall Thermostat; Remote Control; Wall Switch - Regency P33CE-NG Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

INSTALLATION
Optional

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram. Use
table below to determine the maximum wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
1) 4 AA batteries must be installed in the battery pack to operate the burner switch.
2) Install 2 AA batteries per side and connect as shown below.
42

REMOTE CONTROL

Use the Regency
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very important).
Run wires from the fi replace to that location.
2) Connect the two wires to the gas valve. See
wiring diagram. Optional wall switch GT/GTM/
GTMF using wire 0.584.907
3) Install 3 AAA alkaline batteries in transmitter and
4 AA alkaline batteries in the receiver. Install
the receiver and its cover in the wall. Switch
the remote receiver to "remote" mode. The
remote control is now ready for operation.
9 Ft.
BATTERY INSTALLATION
Optional
®
Remote Control Kit approved
CAUTION
Do not wire millivolt
remote control wires
to 120V wire.
Optional

WALL SWITCH

1) Run the supplied 10' of wire through the right
or left side gas inlet opening. Be careful not to
damage wire.
Note: We recommend a maximum of 10' of
wire but if you wish to go with a longer
run, use the Thermostat Wire Table.
2) Connect the wire to a wall switch and install
into the receptacle box. Also attach wires to
the valve as shown below.
CAUTION
Do not wire millivolt
wall switch wires
to 120V wire.
P33CE Direct Vent Gas Fireplace

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P33ce-lp

Table of Contents