Combustible Mantels - Regency P33CE-NG Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the
diagram below.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
This drawing is to scale at 1:6 (one inch = 6 inches). Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Combustible mantel leg clearances as per diagrams below:
P33CE Direct Vent Gas Fireplace

COMBUSTIBLE MANTELS

Mantel Clearances
12
10
8
6
12" (305mm)
16
7-1/2"(191mm)
14
0" - 3-1/2" (89mm)
12
10
15-3/4" (400mm)
8
6
13-3/4"(349mm)
4
11-3/4"(298mm)
2
0
24-1/4"(616mm)
to floor
4
2
Drywall
Non-combustible material
3"(76mm)
Standoff
Top opening
of Unit
Side View
INSTALLATION