Clearances - Regency P33CE-NG Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

INSTALLATION
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fi replace are defi ned by
standoffs. The metal ends of the standoff may NOT
be recessed into combustible construction.
C
F
Clearance:
A: *Front Floor Clearance (min.)
B: *Sidewall (on one side)
C: *Ceiling
(room and/or alcove)
D: Alcove Width
E: Alcove Depth
F: Mantel
G: Mantel Clearances
10

CLEARANCES

Dimension
Measured From:
0"
Underside of Unit
9" (229mm)
Side Opening of Unit
30" (762mm)
Top Opening of Unit
84" (1219mm)
Sidewall to Sidewall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
12" (305mm)
15-3/4" (400mm)
From Top Opening of Unit
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
C
Horizontal - Top
Horiztonal - Side
Horiztonal - Bottom
Vertical (Flex Vent)
Vertical (Rigid)
Fire hazard is an extreme risk if these
clearances are not adhered to.
Close to Ceiling
Flue Clearances
2-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/4"
Warning
P33CE Direct Vent Gas Fireplace

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P33ce-lp

Table of Contents