Rheem CRTGH-95X Series Use And Care Manual page 48

94% condensing tankless
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
WaterSupply
Water Supply Connections (cont.)
Toensureproperoperationofthewaterheater,follow
thesewaterpressureguidelines.
• O perationofthewaterheaterrequiresaminimum
waterpressureof14psi(97kPa)andaminimum
waterflowrateof0.4gpm(1.5lpm).
• W aterpressureof40psi(276kPa)isrequiredto
achievemaximumflowrate.
• T omaintainproperperformance,theremustbe
sufficientwatersupplypressure.
RequiredWaterPressure=
Water Supply Installation
NOTICES:
• U seonlyTeflontapeonallCOLDandHOTwater
connections.
• I fthewaterflowresistanceofashowerheadis
toohigh,theburnerinthewaterheaterwillfailto
ignite.Keepallshowerheadscleanfromdebristhat
couldcauseadditionalpressuredrop.
• I fusingmixingvalvesontheoutlet,chooseonethat
preventsCOLDwaterpressurefromovercomingHOT
waterpressure.
• I fmultiplewaterheatersareinstalledinamanifold
system,thewaterpipingMUSTbein"parallel"and
thewaterpressureateachwaterheatershouldbe40
psi(276kPa).
1
 InstallaCOLDwatershut-offvalveneartheinlet
lineonthewaterheater.Thisvalvewillbeusedfor
servicinganddrainingpurposes.
NOTICE:

withsmallerdiametersthanthewatersupply
connectionofthewaterheater.
48
Min.OperatingWaterPressure
(14psi[97kPa])
+PipePressureLoss
+FaucetPressureLoss
+SafetyMargin
(morethan5psi[34kPa]).
Itisnotrecommendedtousepipes
• T osupplyHOTwatertoupperfloors,additionalwater
pressurewillberequired(0.44psi[3kPa]
perfootofheight).Calculatethedistancebetween
thewaterinletofthewaterheater(groundlevel)to
theHOTwaterfaucetfarthestawayfromthewater
heater(upperfloorlevel).
• W ellwatersystemsshouldbesettoensurea
minimumsystempressureof40psi(276kPa).The
pressureshouldremainconstantandstableduring
theoperationofthewaterheater.
• G ravitywaterpressureisnotrecommended.When
thewaterissuppliedfromawatersupplytank,the
heightofthetank,thediameterofthesupplypipes,
andtheirrelationtowaterpressureneedtobetaken
intoconsideration.
2
 Beforeattachingthewaterlinetothewaterheater,
opentheshut-offvalve.Runthewateruntilit
haspurgedallcontaminants(sand,debris,air,
caulking,etc.).
3
 InstallaservicevalveontheendoftheCOLDwater
supplylineandconnectittothewaterinletonthe
waterheater.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents