Rheem CRTGH-95X Series Use And Care Manual page 40

94% condensing tankless
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
VentingforDirect-VentWaterHeater(cont.)
Wall Plate
(recommended)
Approximately
4" recommended
HorizontalVentInstallation
WARNING:
–Solventcementsandprimersarehighlyflammable.
Provideadequateventilationanddonotassemblenear
heatsourceoropenflame.Donotsmoke.Avoidskin
oreyecontact.Observeallcautionsandwarningson
materialcontainers.
CAUTION:
manufacturer-approvedSchedule40PVC(foamcore
isnotpermittedatanytime),Schedule80PVC,CPVC,
ABSorUL1738-listedCategoryIIIStainlessSteel.
Nootherventmaterialispermitted.ForCanada,
installationsmustfollowULCS636forexhaustventing.
Joining PipesandFittings
Allpipe,fittings,solventcement,primers,and
procedures,fortheU.S.,mustconformtoAmerican
NationalStandardsInstituteandAmericanSociety
forTestingandMaterials(ANSI/ASTM)standards.For
Canada,allpipe,fittings,solventcement,primers,
andproceduresmustconformtoULC-S636andvent
manufacturerspecifications.
CAUTIONS:
• D oNOTusesolventcementthathasbecomecurdled,
lumpy,orthickened.
• D oNOTthinsolventcement.Observeshelf
precautionsprintedonthecontainers.
• F orapplicationsbelow32°F,useonlylower
temperature-typesolventcement.
• A ppropriatesolventandcleanermustbeusedforthe
typeofventpipeused(PVC,CPVC,orABS).
40
Downward Slope
to Outside termination
12"
Exhaust Vent Pipe
(300 mm)
Inspection
Access Panel
(Optional)
Dangeroffireorbodilyinjury
Usetanklesswaterheater

Air Intake Pipe
Ceiling
Inspection
Access Panel
(Optional)
Cleaner-PrimerandMedium-BodySolvent
Cement
Alljointsinventpipingmustbeproperlysealed,and
werecommendusingthefollowingmaterial:
PVCmaterialsshoulduseASTMD-2564-gradecement.
CPVCmaterialsshoulduseASTMF-493-gradecement.
ABSmaterialsshoulduseASTMD-2235-gradecement
(ABSisnotallowedforexhaustventinCanada).
CementingJoints
1. C utpipeendsquare;removejaggededgesand
burrs.Chamferendofpipe;thencleanfitting
socketandpipejointareaofalldirt,grease,or
moisture.
2.  A ftercheckingpipeandsocketforproperfit,wipe
socketandpipewithcleaner-primer.Applyaliberal
coatofprimertoinsidesurfaceofsocketand
outsideofpipe.
3. A pplyathincoatofcementevenlyinthesocket.
Quicklyapplyaheavycoatofcementtothepipe
andinsertpipeintofittingwithaslighttwisting
motionuntilitbottomsout.
4. H oldthepipefittingfor30secondstopreventthe
taperedsocketfrompushingthepipeoutofthe
fitting.
5. W ipeallexcesscementfromthejointwitharag.
Allow15minutesbeforehandling.Curetimewill
varyaccordingtofit,temperature,andhumidity.
NOTICES:
• C ementmustbefluid;ifnot,recoatwithfresh
cement.
• S tirthesolventfrequentlywhileusing.Useanatural
bristlebrushorthedaubersuppliedwiththecan.
Theproperbrushsizeisoneinch.

Hide quick links:

Advertisement

Table of Contents
loading