Number Of Beeps - Error; Beeper Volume Max; Good Read Delay - Honeywell Xenon 1900 User Manual

Area-imaging scanner
Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

Programming Chart
inside the back cover of this manual. Default = 1.
Number of Good Read Beeps/LED Flashes
Number of Beeps – Error
The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 - 9. For
example, if you program this option to have five error beeps, there will be five error beeps and five LED flashes in response
to an error. To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the
Save bar code on the
Programming Chart
inside the back cover of this manual. Default = 1.
Number of Error Beeps/LED Flashes

Beeper Volume Max

Note: The Beeper Volume Max feature only applies to Granit products.
Scan the following bar code to set all error and good read beeps to the maximum volume. This feature also sets the
Beeper
Pitch – Good Read
to the highest level.
Beeper Volume Max

Good Read Delay

This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay).
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)
4 - 5

Advertisement

Table of Contents
loading

Table of Contents