Inverter wall mounted type room air-conditioner split system, air to air heat pump type
Table of Contents

Advertisement

2.2 Range of usage & limitations
Item
Indoor return air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Power source voltage
Voltage at starting
Frequency of ON-OFF cycle
ON and OFF interval

2.3 Exterior dimensions

(1) Indoor unit
Models SRK50ZHX-S, 60ZHX-S
A
120
220
3
8
Piping for Liquid
Piping hole(¿6 )
Models
890
6 0
120
4 0
220
3
4
Piping for Gas 491.1(¿12.7)
Drain hose 20.8 (¿16)
9.1(¿6.3 )
Piping hole(¿6 )
SRK50ZHX-S, 60ZHX-S
Cooling operation : Approximately 18 to 32˚C
Heating operation : Approximately 15 to 30˚C
Cooling operation : Approximately -15 to 46˚C
Heating operation : Approximately -15 to 21˚C
Max. 30m
Max. 20m (Outdoor unit is higher)
Max. 20m (Outdoor unit is lower)
Rating 10%
Min. 85% of rating
Max. 7 times/h
(Inching prevention 5 minutes)
Max. 3 minutes
220
Terminal block
122.1
26
60
4
-
-
3
Piping hole right (left)
881.9
VIEW A
Unit: mm
60
21