Mitsubishi SRK20ZSX-S User Manual

Heavy industries packaged air conditioner

Advertisement

Quick Links

USER'S MANUAL
USER'S MANUAL
AIR-CONDITIONER
MITSUBISHI HEAVY INDUSTRIES PACKAGED AIR CONDITIONER
MITSUBISHI HEAVY INDUSTRIES LTD. PACKAGED AIR CONDITIONER
USER'S MANUAL
Ceiling cassette −4 way− (FDT)
Ceiling cassette −4 way− (FDT)
Ceiling cassette −4 way Compact (600×600mm)− (FDTC)
Ceiling cassette −4 way Compact (600×600mm)− (FDTC)
Duct connected −High static pressure− (FDU)
Duct connected −High static pressure− (FDU, FDUS)
PACKAGED AIR CONDITIONER
Duct connected −Middle static pressure− (FDUM)
Duct connected −Middle static pressure− (FDUM)
Ceiling Suspended (FDE)
Ceiling Suspended (FDE)
Floor Standing (FDF)
FD series
Floor Standing (FDF)
Inverter Packaged Air-conditioners
Ceiling cassette -4 way - (FDT)
Ceiling cassette -4 Compact (600x600mm)- (FDTC)
SRK20ZSX-S
Duct connected -High static pressure- (FDU)
SRK25ZSX-S
Duct connected -Middle static pressure- (FDUM)
SRK35ZSX-S
Ceiling suspended (FDE)
SRK50ZSX-S
Floor standing (FDF)
SRK60ZSX-S
KX KXR
VRF inverter multi-system Air-conditioners
Ceiling cassette -4 way- (FDT)
Ceiling cassette -4 way Compact (600x600mm)- (FDTC)
Ceiling cassette -2 way- (FDTW)
Ceiling cassette -1 way Compact- (FDTQ)
Ceiling cassette -1 way- (FDTS)
Duct connected -High static pressure- (FDU)
Duct connected -Middle static pressure- (FDUM)
Ceiling suspended (FDE)
Wall mounted (FDK)
Floor standing -2 way- (FDFW)
Floor standing (with casing) (FDFL)
Floor standing (without casing) (FDFU)
Duct connected -Low static pressure- (FDUT)
Duct connected -Compact&Flexible- (FDUH)
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
<WIRED REMOTE CONTROL>
Duct connected -High static pressure outdoor air processing unit (FDU -F)
RC-E5
Please refer to the manual provided with WIRED REMOTE
CONTROL (RC-EX series) and WIRELESS REMOTE
CONTROL (RCN-E2, EK2 series)
Please refer to the manual provided with eco touch REMOTE
Veuillez vous référer au manuel fourni avec la
CONTROL
TÉLÉCOMMANDE FILAIRE (série RC-EX) et la
S'il vous plaît se référer à la documentation fournie avec la
TÉLÉCOMMANDE SANS-FIL (série RCN-E2, EK2)
eco touch télécommande
Siehe bitte die mit KABEL-FERNBEDIENUNG (RC-EX-Serie)
und DRAHTLOSE FERNBEDIENUNG (RCN-E2-, EK2-Serie)
Bitte beachten Sie die Dokumentation, die mit der eco touch
mitgelieferte Bedienungsanleitung
Fernbedienung kam
This air-conditioner complies with following directive.
This air-conditioner complies with EMC Directive 2004/108/EC
Machinery 2006/42/EC
(replaced by 2014/30/EU on 20/4/2016), LV Directive 2006/95/
Low Voltage 2014/35/EU
EC (replaced by 2014/35/EU on 20/4/2016).
EMC 2014/30/EU
CE marking is applicable to the area of 50 Hz power supply.
Pressure Equipment 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE marking is applicable to the area of 50 Hz power supply.
Ce climatiseur est conforme à la directive CEM 2004/108/CE
Ce climatiseur est conforme aux directives suivantes.
(remplacée par la directive 2014/30/UE le 20/04/2016) et à la
Machines 2006/42/CE
directive basse tension 2006/95/CE (remplacée par la directive
Basse tension 2014/35/UE
2014/35/UE le 20/04/2016).
CEM 2014/30/UE
La marque CE s'applique aux régions alimentées en courant
Équipements sous pression 2014/68/UE
de 50 Hz.
RoHS 2011/65/UE
Écoconception 2009/125/CE
La marque CE s'applique aux régions alimentées en courant
de 50 Hz.
ORIGINAL INSTRUCTIONS
USER'S MANUAL
AIR-CONDITIONER
MANUEL DE L'UTILISATEUR
CLIMATISEUR
ANWENDERHANDBUCH
KLIMAGERA ¨ T
ISTRUZIONI PER L'USO
CONDIZIONATORE D'ARIA
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
AIRCONDITIONING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
ΚΛΙΜΑΤΙΣΤΙΚΟ
<eco touch REMOTE CONTROL>
RC-EX series
КОНДИЦИОНЕР ВОЗДУХА
Consultare il manuale in dotazione con TELECOMANDO
CABLATO (serie RC-EX) e TELECOMANDO SENZA FILI
(serie RCN-E2, EK2)
Si prega di fare riferimento alla documentazione fornita con il
KULLANIM KILAVUZU
Consulte el manual suministrado con el MANDO A
eco touch telecomando
DISTANCIA ALÁMBRICO (serie RC-EX) y el MANDO A
Por favor, consulte la documentación que viene con el eco
DISTANCIA INALÁMBRICO (serie RCN-E2, EK2)
touch mando a distancia
Raadpleeg de handleiding die is meegeleverd met de
BEDRADE AFSTANDSBEDIENING (RC-EX-reeks) en
Raadpleeg de documentatie die bij de eco touch afstandsbe-
DRAADLOZE AFSTANDSBEDIENING (RCN-E2-, EK2-reeks)
diening
Diese Klimaanlage erfüllt die folgende Richtlinie.
Dieses Klimagerät erfüllt die Richtlinien zur elektromagnetischen
Maschinen 2006/42/EC
Verträglichkeit 2004/108/EC (ersetzt durch 2014/30/EU am
Niederspannung 2014/35/EU
20/4/2016) und die Niederspannungsrichtlinien 2006/95/EC
EMV 2014/30/EU
(ersetzt durch 2014/35/EU am 20/4/2016).
Druckgeräte 2014/68/EU
Die CE-Marke gilt für Bereiche mit einer Netzstromversorgung
RoHS 2011/65/EU
Ökodesign 2009/125/EC
von 50 Hz.
Die CE-Marke gilt für Bereiche mit einer Netzstromversorgung
von 50 Hz.
Questo condizionatore d'aria è conforme alla Direttiva EMC
Questo condizionatore d'aria è conforme alla seguente direttiva.
2004/108/CE (sostituita dalla Direttiva 2014/30/UE il 20/4/2016)
Macchinario 2006/42/CE
e alla Direttiva LV 2006/95/CE (sostituita dalla Direttiva 2014/35/
Bassa tensione 2014/35/UE
UE il 20/4/2016).
EMC 2014/30/UE
Il marchio CE è applicabile alla fascia di alimentazione 50 Hz.
Apparecchiature a pressione 2014/68/UE
RoHS 2011/65/UE
Ecodesign 2009/125/CE
Il marchio CE è applicabile alla fascia di alimentazione 50 Hz.
ENGLISH
ORIGINAL INSTRUCTIONS
FRANÇAIS
DEUTSCH
ITALIANO
ESPAN ˜ OL
NEDERLANDS
PORTUGUÊS
ΕΛΛΗΝΙΚΑ
РУССКИЙ
<WIRELESS REMOTE CONTROL>
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ U
Consulte o manual fornecido com o CONTROLO REMOTO
COM FIOS (série RC-EX) e o CONTROLO REMOTO SEM
FIOS (série RCN-E2, EK2)
Por favor, consulte a documentação que veio com o eco
TÜRKÇE
Σας παρακαλούμε να ανατρέξετε στο εγχειρίδιο που παρέχεται
touch controle remoto
μαζί με το ΕΝΣΥΡΜΑΤΟ ΤΗΛΕΧΕΙΡΙΣΤΗΡΙΟ (σειρά RC-EX) και το
Ανατρέξτε στην τεκμηρίωση που συνόδευε το eco touch
ΑΣΥΡΜΑΤΟ ΤΗΛΕΧΕΙΡΙΣΤΗΡΙΟ (σειρές RCN-E2, EK2)
τηλεχειριστήριο
Пожалуйста, обратитесь к руководству, которое поставляется с ПРОВОДНЫМ
ПУЛЬТОМ ДИСТАНЦИОННОГО УПРАВЛЕНИЯ (серия RC-EX) и БЕСПРОВОДНЫМ
Пожалуйста, обратитесь к документации, поставляемой
ПУЛЬТОМ ДИСТАНЦИОННОГО УПРАВЛЕНИЯ (серия RCN-E2, EK2)
с eco touch дистанционным управлением
Este aire acondicionado cumple con la siguiente directiva.
Este equipo de aire acondicionado cumple con la Directiva de
Máquinas 2006/42/CE
Compatibilidad Electromagnética: 2004/108/CE (reemplazada
Baja tensión 2014/35/UE
por la Directiva 2014/30/EU el 20/4/2016), y con la Directiva
EMC 2014/30/UE
de Baja Tensión 2006/95/CE (reemplazada por la Directiva
Equipos a presión 2014/68/UE
2014/35/EU el 20/4/2016).
RoHS 2011/65/UE
Ecodiseño 2009/125/CE
La indicación CE sólo corresponde al área de suministro
La indicación CE sólo corresponde al área de suministro
eléctrico de 50 Hz.
eléctrico de 50 Hz.
Deze airconditioner voldoet aan EMC-Richtlijn 2004/108/
Deze airconditioner voldoet aan de volgende richtlijn.
EC (vervangen door 2014/30/EU op 20/4/2016), LV-Richtlijn
Machine 2006/42/EC
2006/95/EC (vervangen door 2014/35/EU op 20/4/2016).
Laagspanning 2014/35/EU
CE-markering is van toepassing op het gebied met een net-
EMC 2014/30/EU
stroom van 50 Hz.
Drukapparatuur 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE-markering is van toepassing op het gebied met een net-
stroom van 50 Hz.
ORIGINAL INSTRUCTIONS
USER'S MANUAL
MANUEL DE L'UTILISATEUR
USER'S MANUAL
ANWENDERHANDBUCH
ENGLISH
MANUEL DE L'UTILISATEUR
FRANÇAIS
ISTRUZIONI PER L'USO
ANWENDERHANDBUCH
DEUTSCH
MANUAL DEL PROPIETARIO
ISTRUZIONI PER L'USO
ITALIANO
GEBRUIKERSHANDLEIDING
MANUAL DEL PROPIETARIO
ESPAÑOL
MANUAL DO UTILIZADOR
GEBRUIKERSHANDLEIDING
NEDERLANDS
О∆НГІЕΣ ХРНΣНΣ
MANUAL DO UTILIZADOR
PORTUGUÊS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ОΔНГІЕΣ ХРНΣНΣ
ЕΛΛΗNIKA
KULLANIM KILAVUZU
РУССКИЙ
KULLANIM KILAVUZU
TÜRKÇE
eco touch uzaktan kumanda ile birlikte gelen belgelere bakın
eco touch uzaktan kumanda ile birlikte gelen belgelere bakın
Este ar condicionado está em conformidade com as seguintes directivas.
Este aparelho de ar condicionado está em conformidade com
Máquinas 2006/42/CE
a Directiva EMC 2004/108/CE (substituída pela 2014/30/UE
Baixa tensão 2014/35/UE
a 20/4/2016) e a Directiva LV 2006/95/CE (substituída pela
EMC 2014/30/UE
2014/35/UE a 20/4/2016).
Equipamentos sob pressão 2014/68/UE
A marca CE aplica-se à zona de fornecimento de energia a
RoHS 2011/65/UE
Concessão ecológica 2009/125/CE
50 Hz.
A marca CE aplica-se à zona de fornecimento de energia a
50 Hz.
Το συγκεκριμένο κλιματιστικό συμμορφώνεται προς την Οδηγία
Το συγκεκριμένο κλιματιστικό συμμορφώνεται προς καθεμιά από
2004/108/ΕΚ περί ηλεκτρομαγνητικής συμβατότητας (η οποία
τις οδηγίες που ακολουθούν.
αντικαταστάθηκε από την Οδηγία 2014/30/ΕΕ στις 20/4/2016)
2006/42/ΕΚ περί μηχανημάτων
και προς την οδηγία 2006/95/ΕΚ περί χαμηλής τάσης (η οποία
2014/35/ΕΕ περί χαμηλής τάσης
αντικαταστάθηκε από την Οδηγία 2014/35/ΕΕ στις 20/4/2016).
2014/30/ΕΕ περί ηλεκτρομαγνητικής συμβατότητας (EMC)
Tο οήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz.
2014/68/ΕΕ περί εξοπλισμού υπό πίεση
2011/65/ΕΕ RoHS
PSA012B790A
2009/125/ΕΚ περί οικολογικού σχεδιασμού
PSA012B806B
Tο σήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz.
PSA012B808
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
ESPAÑOL
NEDERLANDS
PORTUGUÊS
ЕΛΛΗNIKA
РУССКИЙ
TÜRKÇE
201611

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi SRK20ZSX-S

  • Page 1 ORIGINAL INSTRUCTIONS USER’S MANUAL USER’S MANUAL ORIGINAL INSTRUCTIONS AIR-CONDITIONER USER’S MANUAL ENGLISH MITSUBISHI HEAVY INDUSTRIES PACKAGED AIR CONDITIONER MITSUBISHI HEAVY INDUSTRIES LTD. PACKAGED AIR CONDITIONER AIR-CONDITIONER USER’S MANUAL ENGLISH USER’S MANUAL MANUEL DE L’UTILISATEUR ORIGINAL INSTRUCTIONS Ceiling cassette −4 way− (FDT) Ceiling cassette −4 way−...
  • Page 2: Table Of Contents

    Please read these alarm”. produced by Mitsubishi Heavy Industries. Please read through this manual before this User’s Manual carefully before using your air-conditioner. After reading, please store Thank you very much for your purchase of this packaged air conditioning system “SAFETY PRECAUTIONS”...
  • Page 3 OPERATION PRECAUTIONS CAUTION The preventive measures If the unit has been that the density of leaked submerged under water Do not use for particular DANGER refrigerant does not exceed due to a natural disaster purpose such as the This appliance can be the limit is necessary in case such as flood or typhoon, storage of food, animals and...
  • Page 4 Do not install the unit Do not place any other Do not operate the air Do not operate or stop the where the airflow is electric appliances or conditioner while the air unit by using the power directly blown to animals and household goods below or filter is removed.
  • Page 5: How To Use

    HOW TO USE< WIRED REMOTE CONTROL > PRECAUTIONS FOR RELOCATION NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS Before repairing or (Wired remote control) OR REPAIRING checking indoor unit, be • The figure below shows the remote control with the cover opened. Note that the items in the liquid Wired remote control crystal display (LCD) area are shown for explanation purpose. sure to turn off “Indoor unit Pull the cover downwards to open. cAUtion power supply breaker”. Ventilation display Weekly timer display Never perform any Ventilation display...
  • Page 6: How To Perform The Timer Operation

    HOW TO OPERATE HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL > < WIRED REMOTE CONTROL > • In order to protect both indoor/outdoor air conditioners, keep the power supply on for six hours before initial operation. (The ATTENTION THE SELECTION OF TIMER MODE crank case heater is energized in order to heat up the compressor.) Do not turn off the power supply.
  • Page 7: How To Perform The Timer Operation

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL > SETTING THE TIME SLEEP TIMER MODE Timer operation is performed based on the time of the clock which is set by the following steps. Make sure to After a certain period of time has elapsed, operation Press TIMER button.
  • Page 8: On Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL > ON TIMER MODE WEEKLY TIMER MODE The unit starts to operate at the set time. It is possible to set temperature at which you want to start the operation. Selection of Weekly timer mode Only one setting is applicable to each operation.
  • Page 9 < WIRED REMOTE CONTROL > HOW TO PERFORM THE TIMER OPERATION Next setting and exiting Weekly timer mode Press SET button. After “ ” is displayed, “ ” is displayed. ◄ mark next to a number lights. “ ” or “ ”...
  • Page 10 HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL > JWeekly timer Holiday Setting JWeekly timer Checking It is possible to temporarily disable each day’s timer setting by using the Holiday Setting. When the Holiday Setting is cancelled, the timer setting is enabled again. In the Weekly timer mode, select and set “...
  • Page 11: How To Operate In Silent Mode

    HOW TO OPERATE IN SILENT MODE < WIRED REMOTE CONTROL > HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL > TIMER CANCELLATION MODE SILENT MODE When the silent mode is set, the unit operates more silently reducing noise from the outdoor unit. Press TIMER button.
  • Page 12: How To Adjust The Louver

    HOW TO ADJUST THE LOUVER HOW TO SET THE AIRFLOW DIRECTION (IN CASE OF FDT, FDTC, FDE) < WIRED REMOTE CONTROL > (IN CASE OF FDT, FDTC, FDE) <WIRED REMOTE CONTROL> It is possible to change the movable range of the louver on the air outlet from the wired remote control. Once the top and bottom positions ADJUSTING WITH LOUVER BUTTON (Indoor unit with auto swing function) are set, the louver will swing within the range between the top and the bottom positions when swing operation is chosen.
  • Page 13: How To Operate Ventilation

    HOW TO OPERATE VENTILATION (WHEN A VENTILATOR IS INSTALLED) < WIRED REMOTE CONTROL > HOW TO SET THE AIR FLOW DIRECTION < WIRED REMOTE CONTROL > When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless Press SET button (Fixing of the upper of the operation of the air conditioner.
  • Page 14: How To Operate Ventilation

    INSPECTION DISPLAY, FILTER SIGN, AIR CONDITIONER NUMBER, STANDBY AND ROOM TEMPERATURE DISPLAY NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS <WIRELESS REMOTE CONTROL> < WIRED REMOTE CONTROL > WIRELESS REMOTE CONTROL • In order to explain the displays in the liquid crystal display, all of them are shown in the figure below. AIR FLOW display WHEN THE CHECK INDICATOR LIGHT (RED) FLASHES WHEN THE FILTER CLEANING MESSAGE IS DISPLAYED...
  • Page 15: Wireless Remote Control

    HOW TO USE < WIRELESS REMOTE CONTROL > ON – TIMER OPERATION < WIRELESS REMOTE CONTROL > HOW TO OPERATE Operation is started at the setting time. [EXAMPLE] If you would like to start the operation at AM 8:00 • In order to protect both indoor/outdoor air conditioners, keep the power supply on for six hours before initial operation. Do not Press ON timer button.
  • Page 16: How To Adjust The Louver

    HOW TO ADJUST THE LOUVER CHECK INDICATION, FILTER SIGN < WIRELESS REMOTE CONTROL > < WIRELESS REMOTE CONTROL > Ceiling suspended (FDE) UP AND DOWN ADJUSTING WHEN SHORT FLASHING LIGHT ( ) IS SHED FROM THE TIMER/CHECK INDICATOR LAMP (YELLOW) lights for 0.5 seconds and How to move swing louver blinks for 0.5 seconds...
  • Page 17: Fan Speed

    BACKUP BUTTON HOW TO MAINTAIN In case of battery exhausted, or loss or any trouble of remote control, the air conditioner can be operated with the BACKUP button on the How to clean the Air Filter indoor unit display part. Clean the filter frequently for economical operation.
  • Page 18: How To Maintain

    TROUBLE SHOOTING HOW TO MAINTAIN Check the following items before requiring service. Ceiling cassette −4 way Compact (600×600mm) − (FDTC) THE UNIT DOES NOT WORK AT ALL 1. Slide the inlet grille levers in the direction of the arrow ( ), and Is the power supply switch Is there a blackout or is the...
  • Page 19: Preparation Of Heating

    TROUBLE SHOOTING SETTING TO DISABLE BUTTON OPERATION <Wired remote control> The phenomena mentioned below is not malfunction. The following button operations can be disabled. If the button is pressed, “ ” is displayed indicating that the button is disabled, NOTICE and the original display returns.
  • Page 20 MAINTENANCE AND INSPECTION GUIDELINE OF MAIN PARTS OF PACKAGED AIR CONDITIONER This table indicates the details of regular inspection items and their intervals adjustment” or “implementation of parts replacement and repair” according (inspection interval), and the timing of parts replacement under a normal to the result of the regular inspection is indicated as the “maintenance Explanation of symbols use condition.
  • Page 21 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) outdoor [Mainly parts and built-in components]...
  • Page 22 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) Part Name Regular Inspection Preventive Maintenance*...
  • Page 24 Fax : +61-2-8571-7992 http ://www.mhiaa.com.au http ://www.mhiaa.com.au MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD. MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD. 220 Soi Chalongkrung 31, Kwang Lamplatiew, Khet Lad Krabang, Bangkok 10520, Thailand 220, Soi Chalongkrung 31, Kwang Lamplatiew, Khet Lad Krabang, Bangkok 10520, Thailand...

This manual is also suitable for:

Srk25zsx-sSrk35zsx-sSrk50zsx-sSrk60zsx-s

Table of Contents