6.5 Needle bar height
24
Standard :
In the furthest right entry point the hook tip in looping stroke position
should be just above the eye of the needle.
Setting :
–
Dismount the throat plate.
–
Bring the machine in looping stroke position.
–
Check the needle bar height according to the instructions and
correct after loosening the screw 4, if required.
–
Tighten screw 4 again.
Note
Do not turn the needle bar when altering the needle bar height.
4